C O N N E C T I O N S A N D C A B L E S
CONNECTIONS
The fixture features IP65 rated 4pin power/data combination input and output connections.
The wiring diagram below provides the pin details.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM
ENTERING THE FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS
MUST BE INSERTED/SEALED.
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED
WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL
SUPPLIERS) TO PREVENT WATER CORROSION AND/OR ELECTRICAL
SHORT CIRCUIT.
CABLES
ELATION P BAR IP 4pin 16AWG power/data cables are available in various lengths.
See Optional Accessories for details.
MAXIMUM CABLE DISTANCES – 16AWG
The following maximum cable distances apply when using 16AWG cables.
PIXEL DRIVER 4000 to 1
PIXEL BAR IP to PIXEL BAR IP = Maximum 32 feet (10 meters)
Total combined length of cables can NOT exceed = Maximum 98 feet (30 meters)
MAXIMUM CABLE DISTANCES – 12AWG
The following maximum cable distances apply when using 12AWG cables.
PIXEL DRIVER 4000 to 1
PIXEL BAR IP to PIXEL BAR IP = Maximum 32 feet (10 meters)
Total combined length of cables can NOT exceed = Maximum 213 feet (65 meters)
www.elationlighting.com
st
PIXEL BAR IP = Maximum 50 feet (18 meters)
st
PIXEL BAR IP = Maximum 50 feet (18 meters)
14
PIN #1
-
(+) Power
PIN #2
-
Data
PIN #3
-
CLK (clock pin)
PIN #4
-
(-) Power