7. Programming the electronic lock
Before you use your safe for the first time it is necessary, for
security reasons, to enter your personal combination; the factory
combination must not be retained. The lock should be
programmed only with the door open and with the electronic lock
released. Select your new six-digit combination before starting
the easy programming sequence. Do not use any personal data
for this combination, such as birthdays or other information which
could be derived from knowledge about your person. Store your
combination in a safe place so that only you have access to it.
7.1 Programming the master combination
Note: Program only with the door open and the electronic lock released. The green LED must not be lit.
Function
Activate programming mode
Select programming mode
Confirm the entry
Enter the previous six-digit combination °
Confirm the entry
Enter the new six-digit combination
Confirm the entry
Verify the new combination by repeating your
entry
Confirm entry
Cancel
Note:
We can assume no guarantee liability for malfunctions caused
by erroneous reprogramming or application of undue force or
improper treatment nor in case of injury to property or assets
which, for example, is due to a failure to close the safe properly.
8. Troubleshooting in case of malfunction
Problem
Red LED lights for about 3 seconds after
the combination is entered.
Red LED lights for about 3 seconds after
programming a new master combination.
Electronic lock does not respond to any
keypad entries.
The red and green LEDs blink alternately,
ten times.
If it is not possible to open your safe in spite of having carried out the instructions above, then please contact the safe manufacturer.
B7205E_1.pmd
Operation, Button(s)
OK = Green LED blinks twice
Invalid = Red LED lights for 3
seconds
We recommend obtaining suitable insurance coverage to protect
the contents of your safe. Your property insurance sales agent
can provide details.
Possible cause
Invalid combination was entered.
The new master combination was improperly
programmed. The old combination is
retained.
The lock-out period was activated by ente-
ring an invalid combination several times in
sequence.
Low battery charge
Rel. 1 vom 29.10.2003
Operating Instructions 9999-039-0
Response
Comments
° Set for 1 - 2 - 3 - 4 - 5 - 6 at
the factory
Important: Please check to
see that the lock functions
correctly with the new
combination before you close
the door to the container
Remedy
Richtigen Code eingeben.
Repeat the programming of the new
combination as described in Item 7.1 of
the operating instructions.
See Item 4 in the operating
instructions.
Change out the batteries. See Item 6 in
the operating instructions.
Seite 2
Need help?
Do you have a question about the ElCom 7205 and is the answer not in the manual?