Cleaning The Sureflo Valve - WAGNER Procoat 9185G Owner's Manual

Gas-powered airless paint sprayer
Table of Contents

Advertisement

Cleaning the
Sureflo Valve
Start
You will need:
• Wrench
Cleaning or servicing the Sureflo Valve
may be required if the unit has priming
problems. Priming problems may be
prevented by properly cleaning the sprayer
and following the long-term storage steps.
If priming problems persist, you may need
to replace the Sureflo Valve assembly. Call
Technical Service (1-800-880-0993) to order
new Sureflo valve assembly.
1
1. Remove the suction tube.
3
3. Lubricate the O-ring on the Sureflo Valve (b) with
petroleum jelly.
Replace Sureflo Valve assembly by screwing it into
the sprayer. Tighten with the wrench.
21
2
(a)
2. Unscrew the Sureflo Valve assembly (a) from the
sprayer. Visually inspect the inside and outside
of the Sureflo Valve assembly. Clean any paint
residue with the appropriate cleaning solution.
4
(b)
4. Replace suction tube and hand-tighten.