Mitsubishi Electric FR-A7NC Instruction Manual page 69

Plug-in option, cc-link communication function
Hide thumbs Also See for FR-A7NC:
Table of Contents

Advertisement

(3) The relation between the device of the PLC
CPU and remote I/O (RX, RY) of the remote
device station is as follows:
The devices used actually are indicated in
shaded regions.
PLC CPU
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X105F to X1050
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y105F to Y1050
Remote device station
(station 1)
RXOF to RX00
RX1F to RX10
RY0F to RY00
RY1F to RY10
Remote device station
(station 2)
RXOF to RX00
RX1F to RX10
RY0F to RY00
RY1F to RY10
PROGRAMMING EXAMPLES
(4) The relation between the device of the PLC
CPU and remote resister (RWw, RWr) of the
remote device station is as follows:
The devices used actually are indicated in
shaded regions.
PLC CPU
For writing
W100
W101
W102
W103
W104
W105
W106
W107
W108
W109
W10A
W10B
For reading
W000
W001
W002
W003
W004
W005
W006
W007
W008
W009
W00A
W00B
Remote device station
(station 1)
RWw0
RWw1
RWw2
RWw3
RWr0
RWr1
RWr2
RWr3
Remote device station
(station 2)
RWw0
RWw1
RWw2
RWw3
RWr0
RWr1
RWr2
RWr3
63
8

Advertisement

Table of Contents
loading

Table of Contents