Supported Functions - ABB REG615 Product Manual

Generator and interconnection protection
Hide thumbs Also See for REG615:
Table of Contents

Advertisement

Generator and Interconnection Protection
REG615
Product version: 5.0 FP1
Table 2. Supported functions
Function
Protection
Three-phase non-directional overcurrent protection, low stage
Three-phase non-directional overcurrent protection, high stage
Three-phase non-directional overcurrent protection, instantaneous stage
Three-phase directional overcurrent protection, low stage
Three-phase directional overcurrent protection, high stage
Three-phase voltage-dependent overcurrent protection
Non-directional earth-fault protection, high stage
Directional earth-fault protection, low stage
Directional earth-fault protection, high stage
Transient/intermittent earth-fault protection
Negative-sequence overcurrent protection
Negative-sequence overcurrent protection for machines
Residual overvoltage protection
Three-phase undervoltage protection
Three-phase overvoltage protection
Positive-sequence undervoltage protection
Negative-sequence overvoltage protection
Frequency protection
Overexcitation protection
Three-phase thermal protection for feeders, cables and distribution
transformers
Three-phase thermal overload protection, two time constants
Circuit breaker failure protection
Three-phase inrush detector
Master trip
Arc protection
Multipurpose protection
Stabilized and instantaneous differential protection for machines
Third harmonic-based stator earth-fault protection
Underpower protection
Reverse power/directional overpower protection
Three-phase underexcitation protection
Three-phase underimpedance protection
Out-of-step protection
Interconnection functions
Directional reactive power undervoltage protection
Low-voltage ride-through protection
Voltage vector shift protection
Power quality
Current total demand distortion
Voltage total harmonic distortion
Voltage variation
Voltage unbalance
Control
Circuit-breaker control
Disconnector control
Earthing switch control
Disconnector position indication
Earthing switch indication
Synchronism and energizing check
Condition monitoring and supervision
Circuit-breaker condition monitoring
Trip circuit supervision
ABB
IEC 61850
A
PHLPTOC
PHHPTOC
PHIPTOC
1
DPHLPDOC
2
DPHHPDOC
1
PHPVOC
EFHPTOC
1
DEFLPDEF
2
DEFHPDEF
1
INTRPTEF
1)
1
NSPTOC
2
MNSPTOC
ROVPTOV
2
PHPTUV
2
PHPTOV
2
PSPTUV
2
NSPTOV
2
FRPFRQ
6
OEPVPH
T1PTTR
1
T2PTTR
CCBRBRF
1
INRPHAR
1
TRPPTRC
2
(3)
3)
ARCSARC
(3)
MAPGAPC
18
MPDIF
H3EFPSEF
DUPPDPR
DOPPDPR
2
UEXPDIS
UZPDIS
OOSRPSB
DQPTUV
1
LVRTPTUV
3
VVSPPAM
1
CMHAI
4)
(1)
VMHAI
4)
(1)
PHQVVR
4)
(1)
VSQVUB
4)
(1)
CBXCBR
1
DCXSWI
2
ESXSWI
1
DCSXSWI
3
ESSXSWI
2
SECRSYN
1
SSCBR
1
TCSSCBR
2
1MRS758279 B
C
D
1
1
1
1
1
1
TR
1
TR
1
1
1
1
1
2
2
1
1
2
2
2
2
2
2
2
2
2
2
2
2
6
4
1
1
1
1
2)
2)
1
1
1
1
3
3
(3)
3)
(3)
3)
(3)
2)
(3)
2)
18
18
1
1
2
2
3
2
1
1
1
1
1
4)
4)
(1)
(1)
4)
4)
(1)
(1)
4)
4)
(1)
(1)
4)
4)
(1)
(1)
1
1
2
2
1
1
3
3
2
2
1
1
1
2
2
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents