Models; One-Colour Measurement; Two-Colour Measurement - Siemens 7MC3052-1AB68 Operating Instructions Manual

Two-colour pyrometer, 7mc3052-series
Table of Contents

Advertisement

5 Models

Two-colour pyrometer
Type
7MC3052-1AB68 550 - 1400 °C
7MC3052-1AB66
7MC3052-1AC66
7MC3052-1AD66
7MC3052-1AE66
7MC3052-1AF66
7MC3052-1AF67
7MC3052-1AB63
7MC3052-1AC63
7MC3052-3AB68
7MC3052-3AC68

5.1 One-colour measurement

This measurement method is suitable for measurements of targets in areas where
no sighting obstructions, either solid or gaseous, exist. The target must fill the
entire target spot.

5.2 Two-colour measurement

The two-colour measuring method detects the infrared radiation at two different
wavelengths and calculates the quotient from the values obtained.
This measurement method is suitable for measurements of targets that are
partially obscured (either intermittently or permanently) by other objects, openings,
screens or viewing windows that reduce energy, and by dirt, smoke, or steam in
the atmosphere. The two color mode can also be used on targets that do not com-
pletely fill the target spot, provided the background is much cooler than the target.
Focus
Temp. range
distance
700 - 1800 °C
0.033 - 0.045 m
600 - 1400 °C
650 - 1600 °C
Measuring
field size
1.5 m
0.2 m ... ∞
1.08 m
0.12 m ... ∞
1.8 m
1.8 m
0.21 m
4.1 x 0.6 mm
1.0 m
18.5 x 2.7 mm
0.21 m
1.0 m
5
Operating instructions
LED spot
light
Ø 21 mm
190 : 1
Ø 5.6 mm
100 : 1
50 : 1
Ø 8 mm
Ø 16 mm
Ø 1.2 mm
Ø 5.6 mm
no
no
no
no
no
no
no
yes
yes
yes
yes

Advertisement