Variables Accessible Only By Supervision - Carel MuC2SE User Manual

Electronic controller for process chiller
Table of Contents

Advertisement

Par.
Description
Regulation setting parameters: r*
r01
Set point
r02
Differential
r05
Compressors rotation
0 = Disabled
1 = FIFO type
2 = Hours balancing
3 = Do not select
r06
Type of regulation/compressors use
0 = Proportional Input
1 = Proportional Input + neutral zone
2 = Proportional output
3 = Proportional Output + neutral zone
4 = Timed output with neutral zone
r07
Neutral zone differential
r08
Output maximum activation time
r09
Output minimum activation time
r10
Output maximum deactivation time
r11
Output minimum deactivation time
r12
Compressors deactivation differential
r13
Minimum set-point
r14
Maximum set-point
r17
Compensation constant
0 = no compensation
r18
Maximum distance from the set point
r19
Start compensation temperature
r21
Set point from external contact
r25
Compressors deactivation external temperature
-40 = function deactivated
r27
Accumulation vessel suppression (low load)
0=Disabled
1=Enabled
2, 3 = Do not select
r28
Min. compressor running time for low load
r29
Low load differential
r43
Heaters set-point:
0=A4, A8, A11, P16, P19 absolute
1=A4, P16, P19 absolute, A8, A11 relative
2=A8, A11, P16, P19 absolute, A4 relative
3=P16, P19 absolute, A4, A8, A11 relative
4=A4, A8, A11 absolute, P16, P19 relative
5=A4 absolute, A8, A11, P16, P19 relative
6=A8, A11 absolute, A4, P16, P19 relative
7=A4, A8, A11, P16, P19 relative
r45
Relative regulation maximum set point
r46
Relative regulation minimum set point
r47
OFF-Differential of compressor for low temperature
Par.
Description
Firmware parameters: F - r*
H99
Software version
H97
Driver software version
H95
Expansion software version (I/O board)
7.2

Variables accessible only by supervision

On-Off
-
0 = Off; 1 = On
-
Digital input 1
-
Digital input 2
-
Digital input 3
-
Digital input 4
-
Digital input 5
-
Digital input B4
-
Digital output 1
-
Digital output 2
-
Digital output 3
Digital output 4
-
-
Digital output 5
Reset alarms
-
2
µC
SE process chiller +030220416 - rel. 2.3 - 17.05.2018
Level
D
D
F
F
F
F
F
F
F
F
U
U
U
U
U
D
D
F
F
F
F
D
F
F
Level
D
D
D
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
D
0
1
MIN
MAX
U.M.
DEF.
r13
r14
°C/°F
12.0
0.1
50
°C/°F
3.0
0
3
-
0
0
4
-
0
0.1
50
°C/°F
2.0
0
999
s
120
0
999
s
100
0
999
s
120
0
999
s
100
0
50
°C/°F
2.0
-40
r14
°C/°F
-40
r13
176
°C/°F
80
-5.0
5.0
-
0
0,3
20
°C/°F
0,3
-40
176
°C/°F
30
r13
r14
°C/°F
12
-40
80
°C/°F
-40
0
3
-
0
0
999
s
60
1.0
50
°C/°F
3.0
0
7
-
0
r46
176
°C/°F
30
-40
r45
°C/°F
10
0.1
10
°C/°F
1.0
MIN
MAX
U.M.
DERF.
0
99.9
int
-
0
99.9
int
-
0
99.9
int
-
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
31
Disp.
SVP Carel
ModBus®
R/W
-
41
41
R/W
-
42
42
R/W
-
78
285
R/W
-
79
286
R/W
-
45
45
R/W
-
80
287
R/W
-
81
288
R/W
-
82
289
R/W
-
83
290
R/W
-
46
46
R/W
-
47
47
R/W
-
48
48
R/W
-
51
51
R/W
-
52
52
R/W
-
53
53
R/W
-
55
55
R/W
-
65
65
R/W
-
88
295
R/W
-
89
296
R/W
-
58
58
R/W
-
121
328
R/W
-
84
84
R/W
-
85
85
R/W
-
86
86
R/W
Disp.
SVP Carel
ModBus®
R/W
-
1
208
R
V
3
210
R
-
149
356
R
64
64
R/W
53
53
R
54
54
R
55
55
R
56
56
R
57
57
R
58
58
R
59
59
R/W
60
60
R/W
61
61
R/W
62
62
R/W
63
63
R/W
78
78
R/W
Variable type
A
A
I
I
A
I
I
I
I
A
A
A
A
A
A
A
A
I
I
A
I
A
A
A
Variable type
I
I
I
D
D
D
D
D
D
D
D
D
D
D
D
D