Example - Cli Setting Tap And Monitor Ports - Fluke AXTAP1204BT-BT User Manual

Configurable in-line taps. link aggregation taps: axtap1200 series dual-link aggregation taps: axtap2200 series
Table of Contents

Advertisement

Command Line Interface (CLI)
EXAMPLE - COMMAND LINE INTERFACE (CLI)
SETTING TAP AND MONITOR PORTS
Example
AXTAP1200 Series and AXTAP 22060 Series Taps allow multiple network devices/tools to receive the combined
data of multiple Ethernet network segments. The AXTAP1200 Series and AXTAP 22060 Series have hard-wired
in-line network taps. However, any of the remaining Monitor (Any-to-Any) ports can be configured as shown
below in Figure 28. All AXTAP series' ports can be set to be input or output ports by the Command Line
Interface (CLI) as shown below in Figure 46.
The settings for the setup of the ATAPBT-SFP Link aggregation Tap shown in Figure 46 are as
follows:
• Ports 1 and 2 are a hard-wired in-line tap.
• Ports 3 and 4 have been setup as SPAN taps.
• Port 3 has been setup to input aggregated data to a Network IDS from Port 1 and 2's inputs/outputs.
• Port 4 has been setup to input aggregated data to a Probe from Port 1, 2, 3, and 4's inputs.
NOTE: Port 3's Network IDS's network interface card (NIC) can handle both sides of the network conversation
at once. Some network interface cards cannot handle the whole conversation at once and must use two sepa-
rate NICs for each side of the conversation. It can be setup either way to fit your network device/tools' require-
ments.
Figure 56. AXTAP1204BT-SFP Series Link Aggregation Tap application example