Ordering For Pre-Configured Ied - ABB REC650 Product Manual

Relion 650 series
Hide thumbs Also See for REC650:
Table of Contents

Advertisement

Bay control REC650 2.2
Product version: 2.2

17. Ordering for pre-configured IED

Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
To obtain the complete ordering code, please combine code from the tables, as given in the example below.
Example code: REC650*2.2-A02X00- P23-B1A12-AA-CA-B-A3-CD1AX-KXXXXXLXGX. Using the code of each position #1-11 specified as REC650*1-2 2-3-4 4-5 6-7
7-8-9 9-10 10 10-11 11 11
#
1
- 2
REC650*
2.2
-
10
SOFTWARE
Version number
Version no.
Configuration alternatives
Single breaker, double busbar
ACT configuration
ABB Standard configuration
Software options
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
IEC 61850-9-2 Process Bus communication, 4 merging units
Language
First local HMI user dialogue language
HMI language, English IEC
Additional local HMI user dialogue language
No additional HMI language
HMI language, English US
Casing
1/2 x 19" rack casing, 1 TRM
Mounting details with IP40 of protection from the front
No mounting kit included
19" rack mounting kit for 1/2 x 19" case or 2xRHGS6 or RHGS12
19" rack mounting kit for 3/4 x 19" case or 3xRHGS6
19" rack mounting kit for 1/1 x 19" case
Wall mounting kit
Flush mounting kit
Flush mounting kit + IP54 mounting seal
62
GUID-970741C9-5C16-4350-8FD6-106EE3BCECC5 v4
- 3
- 4
-
-
- 11
-
- 5
6
- 7
-
-
Position
#1
2.2
Selection for position #1
Ordering no
#2
1MRK008004-BG
A02
Selection for
position #2
Ordering no
#3
1MRK004001-PP
P23
1MRK004001-PR
P24
1MRK004001-PU
P31
Selection for
position #3
Ordering no
#4
1MRK002930-AA
B1
1MRK002920-UB
Selection for
B1
position #4
Ordering no
#5
1MRK000151-VA
A
Selection for
A
position #5
Ordering no
#6
X
1MRK002420-BB
A
1MRK002420-BA
B
1MRK002420-CA
C
1MRK002420-DA
D
1MRK002420-PA
E
1MRK002420-NA
F
Selection for
position #6
1MRK 511 426-BEN B
- 8
- 9
-
-
X
Notes and rules
Notes and rules
X00
Notes and rules
Options P23 and P24 require two
SFPs placed in pairs.
Notes and rules
X0
A12
Notes and rules
Notes and rules
Wall mounting not recommended
with communication modules with
fiber connection
-
-
ABB

Advertisement

Table of Contents
loading

Table of Contents