[C] -7 (light cyan) to +7 (deep cyan)
[M] -7 (light magenta) to +7 (deep magenta)
[Y] -7 (light yellow) to +7 (deep yellow)
Detail
Sets items for [Detail].
Level: Sets the [Detail] level. (-7 to +7)
Adjust: The following parameters can be selected manually.
Mode: Selects auto/manual setting. (Auto (automatic optimization) / Manual (The details are set manually.))
V/H Balance: Sets the vertical (V) and horizontal (H) balance of DETAIL. (-2 (off to the vertical (V) side) to +2 (off to
the horizontal (H) side))
B/W Balance: Selects the balance of the lower DETAIL (B) and the upper DETAIL (W). (Type1 (off to the lower
DETAIL (B) side) to Type5 (off to the upper DETAIL (W) side))
Limit: Sets the limit level of [Detail]. (0 (Low limit level: likely to be limited) to 7 (High limit level: unlikely to be limited))
Crispning: Sets the crispening level. (0 (shallow crispening level) to 7 (deep crispening level))
Hi-Light Detail: Sets the [Detail] level in the high intensity areas. (0 to 4)
Copy
Copies the settings of the picture profile to another picture profile number.
MENU →
(Camera Settings1) → [Picture Profile] → [Copy]
Reset
Resets the picture profile to the default setting. You cannot reset all picture profile settings at once.
MENU →
(Camera Settings1) → [Picture Profile] → [Reset]
Note
Since the parameters are shared for movie and still images, adjust the value when you change the shooting mode.
If you develop RAW images with shooting settings, the following settings are not reflected.
Black Level
Black Gamma
Knee
Color Depth
If you change [Gamma], the available ISO value range changes.
When using S-Log2 gamma, the noise becomes more noticeable compared to when using other gammas. If the noise still is
significant even after processing pictures, it may be improved by shooting with a brighter setting. However, the dynamic range
becomes narrower accordingly when you shoot with a brighter setting. We recommend checking the picture in advance by test
shooting when using S-Log2.
Setting [ITU709(800%)] or [S-Log2] may cause an error in the white balance custom setup. In this case, perform custom setup
with a gamma other than [ITU709(800%)] or [S-Log2] first, and then reselect [ITU709(800%)] or [S-Log2] gamma.
Setting [ITU709(800%)] or [S-Log2] disables the [Black Level] setting.
If you set [Slope] to +5 in [Manual Set], [Knee] is set to [Off].
S-Gamut is a color space unique to Sony that provides a wide color space equivalent to film cameras. However, S-Gamut setting
of this camera does not support the whole color space of S-Gamut; it is a setting to realize a color reproduction equivalent to S-
Gamut.