4 Initial Setting

The following settings can be made in the initial
setting mode.
Item
Temperature unit
12-hour format/
Time display
24-hour format
Single set point/
AUTO mode
Dual set point
Pair No.
%DFNOLJKW
F
7
8
A
Fig. 4-1
C
B
Fig. 4-2
4.1. Switching to the initial setting mode
1. Press the
‡ ,I WKH ZHHNO\ WLPHU LV HQDEOHG SUHVV WKH
Setting
disappears.)
ºC/ºF
2. Press the
‡ 7KH )XQFWLRQ VHWWLQJ VFUHHQ ZLOO EH GLVSOD\HG DQG WKH IXQFWLRQ 1R A ZLOO EOLQN )LJ 
‡ 3UHVV WKH
 &KHFN WKDW IXQFWLRQ 1R ³´ LV GLVSOD\HG DQG WKHQ SUHVV WKH
‡ 7KH 6FUHHQ GLVSOD\ VHWWLQJ VFUHHQ ZLOO EH GLVSOD\HG )LJ 
0–3
4.2. Changing the temperature unit A [Factory setting:°C] (Fig. 4-2)
On/Off
Press the
‡ (DFK WLPH WKH
 7KH WHPSHUDWXUH LV GLVSOD\HG LQ GHJUHHV &HOVLXV
 7KH WHPSHUDWXUH LV GLVSOD\HG LQ GHJUHHV )DKUHQKHLW
4.3. Changing the time display B [Factory setting: 12-hour format]
Press the
‡ (DFK WLPH WKH
 7KH WLPH LV GLVSOD\HG LQ WKH KRXU IRUPDW
 7KH WLPH LV GLVSOD\HG LQ WKH KRXU IRUPDW
4.4. Changing the AUTO mode C [Factory setting: Single set point]
Press the
‡ (DFK WLPH WKH
 7KH $872 PRGH RSHUDWHV DV WKH XVXDO DXWRPDWLF PRGH 6LQJOH VHW SRLQW 
 7KH $872 PRGH RSHUDWHV XVLQJ GXDO VHW SRLQWV
1
4.5. Changing the pair No. D [Factory setting: 0]
Press the
‡ 6HW WKH SDLU QXPEHU
4
2
Pair No. of wireless
3
remote controller
0
6
1
5
2
3
9
Setting example (when using slim air conditioners)
Independent
system
A
D
E
Simultaneous
twin/triple/
quadruple
system
4.6. Changing the backlight setting E [Factory setting: ON]
Press the
‡ (DFK WLPH WKH
 7KH EDFNOLJKW FRPHV RQ ZKHQ D EXWWRQ LV SUHVVHG
 7KH EDFNOLJKW GRHV QRW FRPH RQ ZKHQ D EXWWRQ LV SUHVVHG
4.7. Completing the settings
Press the
‡ 7KH IXQFWLRQ 1R A EOLQNV (Fig. 4-1)
Press the
‡ The remote controller exits the initial setting mode. (The air conditioner operation is stopped.)
button 1 to stop the air conditioner.
button 2.
button 4 to change the function No.
button 5.
button 5 is pressed, the setting switches between
button 6.
button 6 is pressed, the setting switches between
button 7.
button 7 is pressed, the setting switches between
button 4.
D
to "0"–"3".
Indoor unit setting
Slim air conditioner
Indoor PC board jumper wire
(J41 and J42 settings)
Do not cut
Cut only J41
Cut only J42
Cut both J41 and J42
(1) Same settings
‡ $OO RI WKH XQLWV FDQ EH RSHUDWHG E\ WKH VDPH ZLUHOHVV
remote controller.
Outdoor unit
Outdoor unit
Outdoor unit
Wireless
Wireless
remote
remote
controller
controller
Indoor
Indoor
Indoor
receiver
receiver
unit
unit
unit
Pair No.0
Pair No.0
Pair No.0
Pair No.0
Wireless remote controller operation unit
(2) Separate settings
‡ (DFK XQLW FDQ EH RSHUDWHG RQO\ E\ LWV RZQ ZLUHOHVV
remote controller.
Outdoor unit
Outdoor unit
Outdoor unit
Wireless
Wireless
remote
remote
controller
controller
Indoor
Indoor
Indoor
receiver
receiver
unit
unit
unit
Pair No.0
Pair No.1
Pair No.2
Pair No.0
Pair No.1
Pair No.2
Wireless remote controller operation unit
Outdoor unit
Wireless
Wireless
Indoor
Indoor
Indoor
remote
remote
controller
controller
unit
unit
receiver
receiver
Pair No.0
Pair No.0
Pair No.0
Pair No.0
Wireless remote controller operation unit
button 9.
button 9 is pressed, the setting switches between
button 3.
button 2.
button 8 to disable the timer. (
button 3.
and .
and .
Multi air conditioner
Indoor PC board SW22 settings
SW22-3
SW22-4
ON
ON
OFF
ON
ON
OFF
OFF
OFF
‡ $OO RI WKH LQGRRU 3&
boards and the wire-
less remote controller
are set to the same
Outdoor unit
pair number.
Wireless
Wireless
‡ ,QVWDOO HDFK XQLW ZLWKLQ
remote
remote
controller
controller
the receiving range of
Indoor
receiver
receiver
the wireless remote
unit
controller or have
Pair No.0
the operator move
the wireless remote
controller to operate
each unit.
Outdoor unit
‡ 7KH LQGRRU 3& ERDUGV
and wireless remote
Wireless
Wireless
remote
remote
controllers are set to
controller
controller
Indoor
receiver
receiver
different pair numbers
unit
for each unit.
Pair No.3
Pair No.3
Example of triple system
Wireless
‡ 7KH V\VWHP RSHUDWHV
remote
controller
regardless of which
unit
receiver
indoor unit receives
the signals.
F
and
.
and
.
3