FC 300 Instruction Manual
15-** Drive information
"
Par.
Parameter description
No. #
15-0* Operating Data
15-00 Operating hours
15-01 Running hours
15-02 kWh counter
15-03 Power up's
15-04 Over temp's
15-05 Over volt's
15-06 Reset of kWh counter
15-07 Reset running hours counter
15-2* Historic Log
15-20 Historic log: Event
15-21 Historic log: Value
15-22 Historic log: Time
15-3* Fault Log
15-30 Fault log: Error code
15-31 Fault log: Value
15-32 Fault log: Time
15-4* Drive identification
15-40 FC type
15-41 Power section
15-42 Voltage
15-43 Software version
15-44 Ordered typecode string
15-45 Actual typecode string
15-46 Drive ordering no
15-47 Power card ordering no
15-48 LCP Id no
15-49 SW id control card
15-50 SW id power card
15-51 Drive serial number
15-53 Power card serial number
15-6* Option ident
15-60 Option in slot A
15-61 Slot A option SWversion
15-62 Slot A ordering no
15-63 Slot A option serial number
15-65 Option in slot B
15-66 Slot B option SWversion
15-67 Slot B ordering no
15-68 Slot B option serial number
15-70 Option in slot C
15-71 Slot C option SWversion
15-72 Slot C ordering no
15-73 Slot C option serial number
15-75 Option in slot D
15-9* Parameter info
15-92 Defined parameters
15-93 Modified parameters
15-99 Parameter metadata
default setting
( )
display text
*
50
How to Program
Default value
0 h
0 h
0. kWh
0
0
0
[0] Do not reset
[0] Do not reset
0
0
0 ms
0
0
0 s
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
[ ]
value for use in communication via serial communication port
MG.33.A6.22 - VLT is a registered Danfoss trademark
4-set-up
Change during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion index
74
Uint32
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint32
-3
Uint32
0
Uint8
0
Int16
0
Uint32
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[5]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[8]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[10]
0
VisStr[19]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[10]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[10]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[10]
0
VisStr[30]
0
Uint16
0
Uint16
0
Uint16