Light Transformer (continued)
4. Disconnect wiring and remove screws and
transformer.
Screws
5. Reverse procedure to reassemble.
Light Transformer
Screw
Black/Red
© 2011 Viking Preferred Service
Cover
N White
L1 Red
(to LED Lights)
WARNING
Verify 120 VAC to the transformer. If voltage is not
available, verify input to terminal block and output
from the terminal block to the transformer. Output
voltage from the transformer should be 2.5 VAC.
Note: VGIQ410-3RE2 model shown