Technical Specification - Lincoln Electric ARC TRACKER K3019-1 Operator's Manual

Table of Contents

Advertisement

Technical Specification

ARC TRACKER™
Model
K3019-1
Duty Cycle
100%
Duty Cycle
100%
VOLTAGE
Input [A]
50/60 Hz
120
0.8A
230
0.5A
230
0,5A
* All attachment plugs must comply with the Standard for Attachment Plugs and Receptable, UL498.
VOLTMETER
AMMETER
ENERGY
**Accuracy is expressed as +/- [Percentage of Reading + Digits].
For example: 10A = +/- 10A x 0.02 + 2 = 10A +/- 2.2, or 7.8A to 12.2A
MODEL
HEIGHT
K3019-1
305 mm
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
English
INPUT VOLTAGE AND CURRENT
Input Voltage ± 10%
120-230 V AC, 50/60 Hz
RATED OPERATING RANGE NEMA EW1
44 V DC
RATED OPERATING RANGE IEC60974-1
44 V DC
RECOMMENDED INPUT WIRE
REGION
3 CONDUCTOR, #18 AWG
NORTH
TYPE S, SO, SOO, ST, STO,
AMERICA
STOO OR EQUIVALENT
EXTRA HARD USAGE CORD
EUROPE
3 CONDUCTOR, 1.0 mm
METER ACCURACY (AS SHIPPED)
PHYSICAL DIMENSIONS
WIDTH
220 mm
TEMPERATURE RANGES
3
Input Amperes
1000 A DC
2
HAR
± 2% + 0.1**
± 2% + 2**
± 5%
DEPTH
WEIGHT
380 mm
-10°C TO 40°C
-40°C TO 85°C
0,8-0,5 A
1000 A DC
NEMA 5-15P
(INCLUDED)
ANY NEMA 250V
TYPE*
CEE 7/7
9 kg
English