x
Parameter settings
6.8 Rotary switch setting: Time Program
Parameter
Party
With this operating mode we can set a one-off time for the temporary heating time extension
of the internal heating circuit.
Away
With this operating mode we can set a one-off time for the temporary regulation to the param-
eterised absence temperature.
Vacation
The internal heating circuit provides continuous (24 h per day) regulation to the parameterised
absence temperature (parameter T-Reduced).
A calendar function can be used to enter a time period for the absence.
Holiday
A calendar function can be used to enter a time period for presence.
HC Program 1
In this menu we can parameterise the 1st timer programme for the internal heating circuit.
3 switching cycles with a resolution of 15 minutes can be set. A separate entry for each week-
day is possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles can be parameterised from Monday to Friday, Saturday to Sunday and Mon-
day to Sunday.
HC Program 2
In this menu we can parameterise the 2nd timer programme for the internal heating circuit.
3 switching cycles with a resolution of 15 minutes can be set. A separate entry for each week-
day is possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles can be parameterised from Monday to Friday, Saturday to Sunday and Mon-
day to Sunday.
DHW Program 1
In this menu we can parameterise the 1st timer programme for hot water generation. 3 switch-
ing cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is
possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles can be parameterised from Monday to Friday, Saturday to Sunday and Mon-
day to Sunday.
DHW Program 2
In this menu we can parameterise the 2nd timer programme for hot water generation. 3 switch-
ing cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is
possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles can be parameterised from Monday to Friday, Saturday to Sunday and Mon-
day to Sunday.
Circulation Time
In this menu we can parameterise a timer programme for the circulation pump. 3 switching cy-
cles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible.
Format: (on) hh:mm - hh:mm (off)
Also, the cycles can be parameterised from Monday to Friday, Saturday to Sunday and Mon-
day to Sunday.
Tab. 6-10
Parameter in rotary switch setting "Time Program"
6.9 Rotary switch setting: Remote Param
Parameter
Bus - Scan
Off: No function
On: Control checks which RoCon devices are connected to the system using the CAN bus
lines. Devices that are detected are displayed with their type and data bus ID
(For example: MM#8 = Mixer module with bus ID 8).
The selection and activation of a device with the rotary switch switches the function of the
control unit to that of the selected device (see chapter 3.4.9).
No selection
Activation switches to the local device.
Contr BM1/BE1 #X
Activation switches to the HPSU compact with the bus ID X.
Mix Valve #X
Activation switches to the mixer module with the bus ID X (see section 6.12.1, parameter
[HC Assignment]).
Tab. 6-11
Parameter in rotary switch setting "Remote Param"
34
Designation
Description
Access
Setting range
Factory
Min / Max
setting
BE
HF
E
E
00:00 - 06:00
00:00
E
E
00:00 - 06:00
00:00
E
E
Date on first
-
day
-
Date on last
day
E
E
Date on first
-
day
-
Date on last
day
E
E
See
See
chapter 3.4.7
tab. 3-7
E
E
See
See
chapter 3.4.7
tab. 3-7
E
E
See
See
chapter 3.4.7
tab. 3-7
E
E
See
See
chapter 3.4.7
tab. 3-7
E
E
See
See
chapter 3.4.7
tab. 3-7
Access
Setting range
Factory
Min / Max
setting
BE
HF
E
E
Off
Off
On
E
E
E
E
E
E
BA ROTEX HPSU compact 4 - 09/2013
Increment
1 h
1 h
1 Day
1 Day
15 min
15 min
15 min
15 min
15 min
Increment
-
-
-
-