MAINTENANCE (continued)
MAINTENANCE MODE (AED Maintenance)
The AED Maintenance screen allows the user to select
such options as AED tests, software upgrades, data
backups, and data card functions.
For detailed information about each of the functions
that can be accessed from this screen, refer to the DDU-
2000 Series User Manual, which can be viewed at or
downloaded from www.defi btech.com.
MAINTENANCE MODE (AED Options)
The AED Options screen allows the user to manually
confi gure AED options such as time, date, volume, and
audio recording.
For detailed information about each of the functions
that can be accessed from this screen, refer to the
DDU-2000 Series User Manual, which can be viewed at
or downloaded from www.defi btech.com.
MAINTENANCE MODE (Rescue Options)
The Rescue Options screen allows the user to manually
confi gure rescue options such as rescue protocol and
CPR breathing. (Note: The "Default view" option is
only available on DDU-2450 units.)
For detailed information about the functions that can
be accessed from this screen, refer to the DDU-2000
Series User Manual at www.defi btech.com.
MAINTENANCE MODE (Help Topics)
The Help Topics screen provides a list of available videos
that detail various aspects of using and maintaining the
DDU-2000 Series AED.
To exit Maintenance Mode, turn the unit off by pressing
the ON/OFF button or navigate to the AED Status Screen
by selecting the "Go to main menu" option and then
navigate to and select the "Turn AED off" option.
20
DAC-A2530EN-BK
AED Maintenence
Rescue now
Perform AED test
Upgrade AED
Transfer data to card
Format data card
Run application from card
Go to main menu
AED Options
Rescue now
System time
hh:mm:ss
System date
yyyy mm dd
Volume level
High
Audio recording
Disabled
Status broadcast
Disabled
Go to main menu
Rescue Options
Rescue now
CPR breathing
Disabled
Rescue protocol
AHA
Settings
1 / 2 / 30 / 50 / 100
Default view
Video
Go to main menu
Help Topics
Rescue now
Preparing the patient
Analyzing and shocking
Performing CPR
Replacing the battery
Replacing the pads
Checking the AED status
Replacing the data card
Go to main menu
CLEANING
After each use, clean the DDU-2000 Series AED of any dirt or contaminants on the case and
connector socket. The following are important guidelines to be adhered to when cleaning the
device:
• The battery pack should be installed when cleaning the DDU-2000 Series AED.
• Do not immerse the DDU-2000 Series AED in fl uids or allow fl uids to enter the unit.
• Do not spray cleaning solutions directly on the unit or its connectors.
• Do not use abrasive materials or strong solvents such as acetone or acetone based
cleaning agents.
• To wipe the DDU-2000 Series AED's case clean, use a soft cloth dampened with one of
the following recommended cleaning agents:
– Soapy water
– Ammonia based cleaners
– Hydrogen peroxide
– Isopropyl alcohol (70 percent solution)
– Chlorine bleach (30 ml/liter water)
• Ensure that the connector socket is completely dry before reinstalling the pads cable.
After cleaning, allow the unit to completely dry. Before returning it to service, always
check the AED operational status (refer to "AED Status Screen" on page 18).
Please note that none of the items provided with the DDU-2000 Series AED (including the AED
itself) are sterile or require sterilization.
!
Do not sterilize the DDU-2000 Series AED or its accessories.
WARNING
For more detailed information, refer to the User Manual (at www.defi btech.com).
21
DAC-A2530EN-BK