904] Placement Testing Wireless Devices; 999] Reset To Factory Defaults - DSC HSM2HOST8 Installation Manual

Power series. 2-way wireless transceiver
Table of Contents

Advertisement

H S M 2 H O S T I n s t a l l a t i o n M a n u a l

2.1.10 [904] Placement Testing Wireless Devices

This test is used to determine RF signal status for wireless devices and can be performed at a system keypad or at the individual device. These
instructions pertain to testing at the keypad. For instructions on placement testing at the device, refer to the installation sheet included with the
wireless equipment.
The following test modes are available:
Table 2-8 Wireless Device Placement Test Modes
000
Test all devices
001-
Test wireless zones
128
520
Test all repeaters
550
Test all sirens
600
Test all wireless keys Test individual wireless keys. Once in this section,
700
Test all keypads
Two test results are provided:
• 24-hour: Average results of signal strength testing over a 24-hour period.
• Now: Signal status results of the current test.
During testing, the Ready and Armed LED's flash to indicate data is being received. A flashing Trouble LED indicates RF interference. The fol-
lowing status indicators may be displayed:
Table 2-9 Wireless Device Status Indications
LCD
Icon* LED+
Strong
1
Good
2
Poor
3
1-Way
4
Not Test
5
None
Early
6
Data received
7
from repeater X
*For Icon keypads, digit 1 indicates 24-hour test results; digit 2 indicates Now test results.
+For LED keypads, the first digit indicates 24-hour results; the second digit indicates Now test results.
2.1.11 [990] Show All Devices
The results of [804][000] Test All Devices are displayed in this section. This section is only available if a test has been completed.
[611] Show RF Problems
Similar to section [990] Show All Devices, except that only problematic test results are displayed (i.e., Poor, 1-way, Not Test, Early).
1.1.12 [997] View Module Information
This section is used to display the model, hardware revision and software version of the HSM2HOSTx.

1.1.13 [999] Reset to Factory Defaults

Selecting this option resets all module programming to factory settings. Panel and other module options are retained.
All enrolled wireless devices are tested automatically
in the following order: repeaters, sirens, detectors, key-
pads. View test results in section [990] Show All
Devices.
Test wireless devices individually by zone.
Test each enrolled wireless repeater.
521-528 for repeaters 1-8
Test each enrolled wireless siren.
551-556 for sirens 1-16
press a button on the wireless key to begin the test.
601-632 for wireless keys 1-32.
Test each enrolled keypad
701-716 for keypads 1-16
Status
1, 9
Strong signal strength
2, 10
Good signal strength
3, 11
Poor signal strength
4, 12
The device is operating in 1-way mode only. The
alarm panel cannot configure or control the device
5, 13
Displayed as the Now result if no test was per-
formed.
Always displayed as the 24-hour result when test-
ing wireless keys.
6, 14
Displayed as the 24-hour result when the panel has
been powered up for less than 24 hours.
7
W i r e l e s s D e v i c e S e t u p a n d P r o g r a m m i n g
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsm2host9ulHsm2host4

Table of Contents