[74] Miscellaneous Opening (Disarming) Reporting Codes
Generic
Full
Reporting Reporting
I_____I_____I Opening by Duress Code 33
FF
FF
I_____I_____I Opening by Duress Code 34
FF
FF
FF
FF
I_____I_____I Opening by System Code 40
FF
FF
I_____I_____I Opening by System Code 41
[75] Maintenance Alarm Reporting Codes
FF*
FF
I_____I_____I Battery Trouble Alarm
FF*
FF
I_____I_____I AC Failure Trouble Alarm
I_____I_____I Bell Circuit Trouble Alarm
FF*
FF
FF*
FF
I_____I_____I Fire Trouble Alarm
* New - Skyroute v2.2 generic default was 00.
[76] Maintenance Restoral Reporting Codes
FF*
FF
I_____I_____I Battery Trouble Restoral
FF*
FF
I_____I_____I AC Failure Trouble Restoral
I_____I_____I Bell Circuit Trouble Restoral
FF*
FF
FF*
FF
I_____I_____I Fire Trouble Restoral
* New - Skyroute v2.2 generic default was 00.
[77]*Miscellaneous Maintenance Restoral Reporting Codes
00**
FF
I_____I_____I Phone #1 FTC
00**
FF
I_____I_____I Phone #2 FTC
00**
FF
I_____I_____I Phone #1 FTC Restore
I_____I_____I Phone #2 FTC Restore
00**
FF
* New section [77] changed for Skyroute v2.2.
** For UL Listed applications this reporting code must be activated.
[78]*Test Transmission Reporting Codes
I_____I_____I Periodic Test Transmission
00
FF
00
FF
I_____I_____I System Test
* New section [78] changed for Skyroute v2.2.

Section 8 - Testing

Testing your control to the Central Station
Be sure to perform normal tests with your central station via the land line.
There is a 1-minute delay between successive signals sent by the Skyroute transmitter.
For example: If you trip 3 zones and you have the Skyroute module programmed to send the alarm and restoral reporting codes
for each zone (6 signals in total), it will take about 5 minutes for all the signals to go through. The first signal goes through
immediately. There will be a 1-minute delay before the second signal is sent and another 1-minute delay before the third signal
is sent, etc.
Generic
Full
Reporting Reporting
I_____I_____I Opening by System Code 42
FF
FF
I_____I_____I Auto-Arm Cancellation
FF
FF
FF
FF
I_____I_____I Special Opening
FF*
FF
I_____I_____I Auxiliary Power Supply Trouble Alarm
FF*
FF
I_____I_____I TLM Trouble Code
I_____I_____I General System Trouble
FF*
FF
FF*
FF
I_____I_____I General System Supervisory
FF*
FF
I_____I_____I Auxiliary Power Supply Trouble
FF*
FF
I_____I_____I TLM Restoral
I_____I_____I General System Trouble Restoral
FF*
FF
FF*
FF
I_____I_____I General System Supervisory
00
00
I_____I_____I Event Buffer 75% Full
00
00
I_____I_____I DLS Lead IN
00
00
I_____I_____I DLS Lead OUT
I_____I_____I Delinquency Reporting Code
00
FF
I_____I_____I Skyroute Test TX Code
FF
FF
19
19
19
19
19
Restoral