Connecting just one string to a Multi MPP Tracker in-
verter
Multi MPP Track-
Multi MPP Tracker inverters have 2 independent DC inputs (MPP Tracker). These inputs
er Inverter – Fro-
can be connected to a number of different modules.
nius Primo 10.0–
MPP Tracker 1 has 4 DC+ terminals.
15.0
MPP Tracker 2 has 2 DC+ terminals.
There are a total of 6 DC- terminals.
Connecting 2-6 strings in Multi MPP Tracker mode:
Connecting two solar module fields to a Multi MPP
Tracker inverter
22
WHEN ONLY ONE STRING IS USED
PV 1
DC+1
DC-1
DC+1
*
D1
=
PV 1
PV 1
PV 2
MPP1: each Terminal
I
DC-1
DC-2
max
DC+1
DC+2
DC
DC
1
If only one string is used for connection to
the inverter, connection DC+1 (pin 2) and
DC+2 (pin 1) must be bridged.
The cable cross-section of the DC connec-
max. 36 A to
ting line and bridging wire must be the sa-
a single
me. Bridging the DC terminal is not
DC terminal
necessary because it is bridged internally.
DC-
DC+2
1 2 3 4
1
1
2 2
Set MPP TRACKER 2 to "OFF" when star-
ting for the first time (also possible in the ba-
*
sic menu subsequently).
If the Multi MPP Tracker inverter is opera-
D1
ted in Single MPP Tracker mode, the cur-
rents of the connected DC lines are
distributed evenly across both inputs.
Connect the strings separately to the two
MPP Tracker inputs (DC+1/DC+2). The
DC- terminals can be used as desired, sin-
ce they are connected internally.
Set MPP TRACKER 2 to "ON" when star-
ting for the first time (also possible in the ba-
sic menu subsequently).