5.3. Checking Range
The next test is for range accuracy. Exit Continuous Output Mode, and select Circular
Pattern Mode. Set the WX-PA range to 120 nm, and the bearin,ij increment to 30 degrees.
Press ENTR to start the test strike output. Set the Stormscope
range to 200 nm and verify
that a circle of discharge points is plotted outside the 100 mile range ring, spaced 30
degrees apart.
Decrease the WX-PA test strike range to 15 nm, switch the stormecope' to the 25 mile
range, and verify that the discharge points are plotted outside the 12 nm range ring.
Figure 5.4 illustrates the proper displays for this test.