EYPAD
• Each keypad connection on the back panel of the CA-Series Master
Controller corresponds to the room / zone number chosen for your
speakers. Each zone operates independently, so it is very important to
connect the keypad to the correct zone keypad input.
• On List 4 (opposite) copy down the room name to the zone number
from List 3 on pg 6. NOTE: the keypad and the speakers in each room
must be hooked to the corresponding numbered zone.
• Remove the connector and strip 1/8" off each end of the wire insula-
tion. Connect each wire 1 thru 8 using a small jewelers screwdriver.
WIRING RUNS UP TO 100 FEET
For wiring runs of up to 100 feet in length, we recommend
the use of CAT-5 wire. It is inexpensive and color coded for
ease of installation. Due to the qualities of CAT-5 wire, when
using it for keypad control wire with the CA-Series, it is rec-
ommended to use the following color code for maximum
performance.
CAT-5
Number
Brown/White
Brown
Green
Orange/White
Orange
Green/White
Blue/White
Blue
Figure 9 – Connections with CAT-5 wire
1 2 3 4 5 6 7 8
8
C
ONNECTIONS
Type
1
Ground
2
IR Signal
3
12VDC+
4
Source Select
5
Source Select
6
Channel Select
7
Volume
8
Balance
I
F
K
NPUT
ROM
EYPADS
4
3
1 2 3 4 5 6 7 8
CAT-5 WIRE
A
C
T
ONTROLLER
List 4 – Room names should be written below.
Zone 1 _________________
Zone 2 _________________
Zone 3 _________________
Zone 4 _________________
WIRING RUNS FROM 100-200 FEET
For wiring runs exceeding 100 feet and extending up to 200
feet, we recommend the use of 8-conductor 22 AWG strand-
ed wire such as Russound MCW2418.
If using 22 AWG wire, the order in which you wire is not
important as long as you wire in the same order at both the
CA unit as well as the keypad. Use List 5 (below) to write
down the wire you use for each pin number.
NOTE: Wiring runs longer than 200 feet are not recommend-
ed for the CA-Series Keypads.
List 5 –Wire color should be written below.
Pin 1 _______________ Pin 2 _______________
Pin 3 _______________ Pin 4 _______________
Pin 5 _______________ Pin 6 _______________
Pin 7 _______________ Pin 8 _______________
Figure 10 – Connections with 22AWG wire
I
NPUT
4
1 2 3 4 5 6 7 8
8 CONDUCTOR
22AWG STRANDED WIRE
F
K
ROM
EYPADS
3
1 2 3 4 5 6 7 8