The Keypad Ports are located on the back of
the CAS44 in the top left of center. Connections
at the Keypad Ports are made with RJ45 con-
nectors using T568A CAT-5 wire configuration.
For a clean installation when wiring from a
Keypad Port, use an RJ45 CAT-5 patch cable to
connect from the keypad port to an RJ45 wall
plate (optional). Using the same RJ45 T568A
CAT-5 wiring configuration, use CAT-5 from the
RJ45 wall plate to the keypad.
CAT-5 Cable
CAT-5 to Keypad
110 punchdown
(KP4, KPL)
If using more than one keypad in a zone, use an
SA-ZX3 System Keypad Splitter (optional). The
SA-ZX3 supports up to three keypads per zone
and connects directly to the Keypad Port for that
zone. The CAT-5 for the keypads is run to a wall
plate, with RJ45 CAT-5 patch cables between the
wall plate and the SA-ZX3. Always use the RJ45
T568A CAT-5 wire configuration when connecting
keypads.
SA-ZX3
1201A/1A
Power
Supply
INSTALLER

MAKING CONNECTIONS

Keypad Port Connection
CAT-5 Cable