c. Selected: Default
(Deflt)
d. Selected: Macro:
i. MACRO -
(Macro)
ii. MACRO ID –
(MacID)
e. All Other Selections:
3. DEVICE CODE –
(DevCd)
4. KEY FUNCTION –
(KeyFn)
5. SAVE CHANGES? –
(Save?)
# OF SOURCES (#Srcs)
At this field it is necessary to enter the number of sources used in the CAM6.6 system (1 to 6). This
limits the sources displayed on the keypad in the normal running mode when the source button is
pressed, but also limits source selections in the configuration menus. See Source Select
Command & # Of Sources - Flow Chart page 73
ZONE SETUP (ZonSu)
NOTE: This procedure should be performed using the keypad installed in the zone to be configured.
See Zone Setup - Flow Chart page 74
Zone Setup allows the installer to adjust properties of the UNO Keypad controlled CAM6.6 zone. This
series of menus allows the system's zones to be configured for these properties:
ZON VOL TRIM (ZonVT)
MASTER ENABL (MstEn)
1. ZON VOL TRIM -
(ZonVT)
2. SYSON ENABLE -
(SysOn)
Default selects the same device type and device code previously
setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 4)
(To build macros, see Macro Editor page 65)
Macro loads a series of commands which are processed when
activated.
Enter the macro ID number. Menu advances to SAVE CHANGES
(step 5)
Procedure advances to DEVICE CODE (step 3)
Source component code for IR control.
Select a function (Play, Enter, etc.).
Select "yes" to save the changes.
SYSON ENABLE (SysOn)
MUTE ENABLE (MutEn)
This feature allows the installer to adjust the output volume to
each zone. -16 dB (lowest) to 0 dB (max)(-3dB default).
This feature is either disabled or enabled. If disabled (default), an
All On command activated from another zone will not turn on the
INSTALLER
INSTALLATION MENU
PARTY ENABLE (PtyEn)
61