Wiring Instructions; Keypad Wiring; Speaker Wiring - Russound CAM6.6X-S1/S2 Instruction Manual

6-zone, 6-source xm receiver and uno smart keypad
Table of Contents

Advertisement

Do not connect the controller's main power feed until all other connections have been
made and verified. Live connection or removal of the keypad wiring or other wiring
when the system is powered can cause communication problems in the network.
Double-check terminations during each phase of the installation to prevent accidental
damage. Incorrect wiring is the number one cause for non-warranty product damage.

Keypad Wiring

For the UNO-S2 and UNO-S1 keypad, the follow-
ing connections are used to terminate the CAT-5
wire to the 110 punchdown on the keypad:
CAT-5 WIRE COLOR
Brown . . . . . . . . . . . . . . . . . . . +12V
Brown/White . . . . . . . . . . . . . . +12V
Green . . . . . . . . . . . . . . . . . . Ground
Green/White . . . . . . . . . . . . Status In
Orange . . . . . . . . . . . . . . . . . Ground
Orange/White . . . . . . . . . . . . . IR Out
Blue . . . . . . . . . . . . . . . . . . . COM A
Blue/White . . . . . . . . . . . . . . COM B
• To determine the amount of CAT-5 wire
required for the system installation, first
decide how many keypads will be used, then
determine the distance between each intend-
ed keypad location to the intended CAM6.6
location. The maximum recommended wire
run length is 250 feet for each UNO Keypad.
RJ-45 Connections
The CAT-5 T568A wiring standard shown on the
right is used for the RJ-45 terminations.
CAUTION
• Make sure that the entire wire path
between keypads and CAM6.6 is clear and
not obstructed by a floor ceiling joist, or
masonry wall which can't be drilled through.
• Confirm ahead of time that you can drill an
TYPE
outlet hole easily and in an unobtrusive spot
to connect wires with the CAM6.6.
• Label wires with keypad and room location.
This simplifies CAM6.6 hook-up once the key-
pads and speakers are installed.

Speaker Wiring

• Standard 16-gauge 4-conductor stranded
speaker wire can be run up to to 125 feet;
14-gauge wire can be run up to 250 feet.
• When running wire, avoid locations conceal-
ing pipes, heating ducts and AC wiring in the
general vicinity.
• Avoid running wires close to house electri-
cal wiring for any distance. If you have to run
them parallel, make sure to space the wires
at least two feet from the AC line.
INSTALLER

WIRING INSTRUCTIONS

27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cam6.6x-s1Cam6.6x-s2

Table of Contents