Network and WiFI Setup [Advanced System Configuration - Remote WiFi connection Setup)
From the Network and WiFi Setup screen you can set up Ethernet settings using DHCP (default on) or a static IP Address to connect to your network. The IntelliCenter Control System Client Bridge
Wireless Antenna (P/N 523213) provides a wireless connection to your home wireless router.
Configure Network: This screen displays the current IP Address.
System IP: Displays the current System IP Address (using DHCP).
Configure Ethernet: Tap this button to setup the Ethernet settings (DHCP or Static IP Address. Configure Wireless Network: Tap this button to discover nearby wireless networks.
Configure Ethernet Settings (DHCP or static IP Address). Use DHCP (ON Default): IP address is obtained automatically (as displayed) OFF: IP Address is assigned by user.
IP address: Your intellicenter.com IP Address (example; 192.168.1.9),
Configure Wireless Network: Tap the Configure Wireless Network button to display the available wireless within range of the IntelliCenter Control System wireless antenna. Available
Adjust Wireless Transmit Power: Auto (Default). Choose the wireless transmit power from 12 to 23 dBm). Use a higher dBm value to transmit the wireless signal over a longer distance.
Internet Connection Test: Test the Internet connection after the WiFi home wireless connection has been setup. If connected to the Internet, the average response time is
displayed.
Networks: Displays the available wireless networks within range of the IntelliCenter Control System wireless antenna. To connect to a wireless network, tap the name of the wireless
network, the keyboard is displayed to enter a new network name (or leave it blank) to use the current network name. The previous screen displays the System IP and WiFi SSID name.
Subnet Mask / Secondary DNS: 255.255.255.0 Default Gateway: 192.168.1.9 Primary DNS: Server should be provided by your ISP.
Delays [Advanced System Configuration]
Delay Settings: Valve Delay ON or OFF: ON: Filter pump is off (30 seconds) during the delay for pool/spa valve rotation. OFF: No valve pool/spa rotation delay
Heater Cool Down Delay ON or OFF (Cancel Delay): Note: This feature is adjustable from 0 to 10 mins. per heater (largest time minutes per body of water).
ON: Activate the pump during a heater cool down. Pump on during heater cool-down: Select this option if you have a heater or other equipment that requires that the filter pump stay on for five
(5) minutes after the equipment goes off. OFF: Shuts OFF the filter pump immediately. Some heaters require a cool-down cycle before being turned off. This can be accomplished with a setup
procedure in the IntelliCenter Control System which runs the filter pump an additional five (5) minutes to dissipate residual heat built up inside the heater combustion chamber. The delay feature
is mainly for use by service technicians when they want to shut the filter pump off immediately, and know the heater has not been running. IMPORTANT: Heaters manufactured by Pentair Water
Pool and Spa do not require this cool-down period and do not need the delay to be set up.
Freeze Cycle Time (0 to 60 minutes): Freeze Cycle Time: Set the freeze protection pump time from 5 to 60 minutes. Default time is 5 minutes. This feature rotates the valves from the pool to the
spa at the duration of the pump timer.
Override Delays: Tap this button to override (cancel) any system delays currently in progress.
Delay Badge (Yellow): A Yellow badge displayed on the Home screen Pool/Spa icon indicates a Valve rotation (delay) is in progress.