Chemistry (Intellichlor Scg, Intellichem Controller); Heaters - Pentair INTELLICENTER Quick Reference Manual

Control system
Hide thumbs Also See for INTELLICENTER:
Table of Contents

Advertisement

Chemisty (IntelliChlor
SCG and IntelliChem Controller)
®
Chemistry [IntelliChlor
SCG and IntelliChem
Controller]:
®
®
From the Chemistry screen you can configure one IntelliChlor SCGs and up to eight IntelliChem Controllers. Also see: Home
Add IntelliChlor and/or IntelliChem: Tap Chemistry on the Home screen. Tap Add Chemistry.
screen(*): Tap Chemistry to access IntelliChlor and IntelliChem operation summary screens.
Select one IntelliChlor SCG and up to eight IntelliChem Controllers on the Select Chemistry Device. IntelliChlor SCG Settings: For dual body systems, each device is assigned to pool/
spa. For single body systems, select either Body 1 (pool), Body 2 (Spa). Chlorination Output Levels: Set the Pool and Spa chlorine output levels. The system can only generate chlorine
while the filter pump is operating. Set the percentage to produce chlorine. The Spa output 1/20 of the pool output when the Spa mode is switched on. Note: If using the Filter Pump Relay
select Filter Pump Relay and Tap Next. Choose either the Pool or Spa Relay and can set the chlorination output levels and turn Super Chlorination On/Off. Tap the Back arrow to return to
the previous screen and Tap Next.
Super Chlorination (ON): Tap the Start Super Chlorination button to temporarily override the current chlorination output levels with super chlorination (100%
IntelliChem Settings: Address (1-4): Select an address from 1-4 for the IntelliChem Controller. Body Assignment: For dual body systems,
output for the select time (typical 24 hours).
the device is assigned to pool/spa. For single body systems, select either Body 1 (pool), Body 2 (Spa).
Heater
Add Heater: Tap Add Heater to add a new heater type. Select New Heater: Select the heater type from the list of heat sources. Heater types are: Off (no heater installed), Gas Heater, Solar, Heat
Pump, UltraTemp and Hybrid (Heat Pump). Gas Heater Settings: Heater Type: Displays the Heater Type selected. Heater Name: Tap the heater name button to change the heater name. Enter the
hew name and tap Check to save the name and return to the previous screen. Affiliated Body: Assign the heater to a body of water: Pool, Spa or Pool/Spa (shared equipment dual body of water).
Heater Name: Tap the heater name to change the current heater name. Tap Cool Down Delay (min): The gas heater Cool Down Delay (min) can be set from 0 to 10 minutes (5 min. default).
Note: Pentair gas heaters do not require a cool down period.
Heater Pump Settings: Heater Type: Displays the Heater Type selected. Heater Name: Tap the heater name button to change the heater name. Enter the hew name and tap Check to save the
name and return to the previous screen. Affiliated Body: Assign the heater to a body of water: Pool, Spa or Pool/Spa (shared equipment dual body of water).
Start Temperature: Tap the -/+ buttons to decrease or increase the Heat Pump start temperature.
Pool/Spa System without a Heat Source: If the pool/spa system does not have a heat source installed, the Home screen and Pool and Spa screens will not display the Heating Set
Point buttons. The Pool/Spa badge (Yellow, Blue, Green) will display the current water temperature.
Solar and Heat Pump Nocturnal Heater Cool Down Delay
For Solar and Heat Pumps. Use the Cooling Set Point temperature control buttons displayed on the Pool and/or Spa screen to adjust the nighttime temperature of the pool/spa water.
Solar Heater Settings:
Heater Type: Displays the Heater Type selected.
Heater Address (1-16): Assign the Heat Pump or UltraTemp heat pump address. Start Temperature (Heat Pump only): Set the start temperature from 1-12.
Note: Valves A & B and Solar
Heating: For Single Body systems, Valve A is used for SOLAR if you choose SOLAR heating. For Dual Body systems, Valve B is used for SOLAR if you choose SOLAR HEATER.
Cooling
Enabled (UltraTemp only): On/Off: On: Set a Cool-Down Cycle for the Heater to activate the pump during a heater cool-down. Note: Select Pump On during heater cool-down, under the Delays
option. Note: Pentair heaters do not require this feature.
Heater Name: Tap the heater name button to change the heater name. Enter the hew name and tap Check to save the name and return to the previous screen.
Affiliated Body: Assign the heater to a body of water: Pool, Spa or Pool/Spa (shared equipment dual body of water).
Start Temp. Delta (6): The minimum temperature difference to start heating. The temperature range is adjustable from 4°F - 9°F. Factory default is 6.
Stop Temp. Delta (3): The temperature difference at which heating will stop. The temperature range is adjustable from 2°F - 5°F. Factory default is 3.
IntelliCenter Control System Quick Reference Guide
12

Advertisement

Table of Contents
loading

Table of Contents