Typical Gray Bar Pattern For Adjusting Contrast - Runco High Definition Owner's Operating Manual

High definition, 1080p flat panel plasma display with widevision and digital high definition controller with vivix iitm technology
Table of Contents

Advertisement

Operation
PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.
Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:
• The darkest black bars disappear into the background.
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the
one shown in Figure 4-3.
Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast and press ENTER. Adjust the contrast to a point just below which the
white rectangle starts to increase in size.
Brightness and contrast controls are interactive. A change to one
Note
may require a subtle change to the other in order to achieve the
optimum setting.