CONFIGURATION MENU
• 0 Volt (4 mA): Define the pressure (bar or PSI) that should be presented when 0 volts (4 mA) is read by the
NMC-Pro.
• 5 Volt (20 mA): Define the pressure (bar or PSI) that should be presented when 5 Volts (20 mA) is read by
the NMC-Pro.
The NMC-Pro will create a linear graph between the 0 Volt (4 mA) to the 5 Volt (20 mA).
11.13
Cooling Configuration
The cooling configuration screen will only be visible after one (or more) cooling valves have been defined in the
DEVICE LAYOUT
table.
• Pump: Configure a pump to each cooling valve. This setting is not necessary if the cooling pump is not
controlled by the NMC-Pro.
• Main Valve: Configure a main valve to each cooling valve. This setting is not necessary if the cooling doesn't
have a main valve.
11.14
Misting Configuration
• Pump: Configure a pump for each misting valve. This setting is not necessary if the misting pump is not
controlled by the NMC-Pro.
• Main Valve: Configure a main valve to each misting valve. This setting is not necessary if the misting doesn't
have a main valve.
NMC-PRO Installation Manual
Page
122