Mitsubishi Electric A1SJ71AP23Q User Manual page 33

Melsecnet, melsecnet/b local station data link module
Table of Contents

Advertisement

Internal conductor
Applicable cable
3C-2V
5C-2V
4) Solder a contact to the internal conductor.
5) Insert a contact assembly in 4) to a plug shell and screw a
POINT
(1)
When soldering an internal conductor and a contact, pay attention to the
following points.
• Do not swell up the soldered part.
• Properly solder a contact and an insulator of the cable without
making space between them or soldering them too tight.
• Perform soldering immediately so as not to modify the insulator.
(2)
Before removing/mounting the coaxial cable connector, be sure to touch
a grounded metal object to discharge the static electricity from the
human body.
Not doing so may cause failure of the module.
Insulator
B
C
B
6mm (0.24 in. )
7mm (0.28 in.)
Solderd
nut into the plug shell.
16
Clamp and external conductor
C
3mm (0.12 in.)
5mm (0.2 in.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sj71ar23qA1sj71at23bq

Table of Contents