Power Consumption For The Nytro Xp6209 Card - Seagate NWD-WLP4-200 User Manual

Nytro warpdrive series; nytro xp6000 series; flash accelerator cards
Table of Contents

Advertisement

www.seagate.com
Table 3 Status Indicators on a Running System (Continued)
Name
Status
If you experience a problem with your Nytro XP6209 card that you cannot resolve, report it to your FAE. Or if you
obtained the product from an OEM, report it to the OEM. Keep these tips in mind when reporting a problem:
Clearly identify and report the revision level of the Nytro XP6209 card. To view this information, use the ddcli
command, Option 1.
Report the part number (for example, L3-25256-00C) listed on the label, and clearly identify the board revision.
Describe the steps leading up to the error.
Report the operating system version and the host driver version.
3.2.3

Power Consumption for the Nytro XP6209 Card

The Nytro XP6209 card receives power from the PCIe 12-V and 3.3-V power rails.
Use the following data for power consumption.
Table 4 Power Consumption
Model
XP6209-4A1024
Seagate Nytro WarpDrive and Nytro XP6000, Rev. 1.12
Color
Green
On, steady - Normal.
On, blinking - Lets the user locate a specific Nytro WarpDrive6209 card in a rack of servers.
Yellow
On, steady - Warning. One of the following conditions applies:
Temperature warning. If this condition persists, you might damage your Nytro XP6209 card.
Increase cooling for the card or shut down your system to prevent damage.
Other component issues: Run the list and health commands in the ddcli utility to determine
which component has an issue.
Red
On, blinking - Firmware fault code:
Run the ddcli utility to determine which component has an issue.
If no information appears, reboot the system and retry.
If no information appears, call your field application engineer.
On, steady - One of the following conditions applies:
One or more SSDs failed.
Failed RAID volume (DD mode).
No RAID volume is configured (DD mode).
At least one SSD has exceeded its temperature.
Backup power store failed.
Other component issues: Run the list and health commands in the ddcli utility to determine
which component has an issue.
If no information appears, reboot the system and retry the utility (DD mode).
Idle
11.3 W
NOTE
For the XP6209-4A1024
random access, 30% write, 70% read, Queue Depth (QD)=32/SSD.
Maximum power I/O was measured at 4-KB, random access, 0% write,
100% read, QD=32/SSD.
LED Description
Typical Power I/O
16.5 W
, typical power I/O was measured at 8-KB,
Nytro XP6209 Card Characteristics
Maximum Power I/O
17.5 W
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents