4.2.3

Operation at rated mains voltage 400 V

Basis of the data
Mains
3/PE AC
Type
E84AVBxx3714
E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024
Assignment
Type
E84AVBxx3714
E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024
EDS84ABD302 EN 4.0
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Operation at rated mains voltage 400 V
Voltage
U
[V]
LN
400
320 - 0 % ... 440 + 0 %
Mains current at I
aN
with external mains
without external
choke
mains choke
I
[A]
I
LN
1.4
1.8
2.2
3.2
3.6
5.0
7.1
Technical data
Voltage range
U
[V]
LN
Output power
U, V, W
[A]
S
[kVA]
LN
aN
1.8
0.8
2.3
1.2
3.2
1.6
4.2
2.1
4.7
2.5
6.2
3.6
10.2
4.8
Mains choke
ELN3-1500H003-001
ELN3-0680H006-001
ELN3-0250H013-001
4
Rated data
Frequency range
f [Hz]
45 - 0 % ... 65 + 0 %
Motor power
4 pol. ASM
P
[kW]
aN
0.37
0.55
0.75
1.1
1.5
2.2
3.0
29