Interfaces

9.1

Alarm Inputs

Active
Configure the alarm triggers for the unit.
Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by closing the contact.
Select N.C.S. (Normally Closed Supervised) if the alarm is to be triggered by opening the
contact.
Select N.O.S. (Normally Open Supervised) if the alarm is to be triggered by closing the
contact.
A supervised alarm transmits both the alarm condition and the tamper condition. Depending
on how the alarm is configured, a short or a break in the alarm's circuit can trigger the tamper
signal.
(NCS and NOS contacts are only present on some cameras)
Name
You can enter a name for each alarm input. If the Live functions are configured accordingly,
this name is displayed below the icon for the alarm input. You can also use the name in the
Forensic Search program function as a filter option for quick search in recordings. Enter a
unique and clear name here.
Caution!
Do not use any special characters, for example &, in the name.
!
Special characters are not supported by the system's internal management.
Note: This name appears in the Digital I/O section of the Live page.
9.2

Alarm Outputs

Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Select the event that triggers the output.
Output name
Enter a name for the alarm output.
Note: This name appears in the Digital I/O section of the Live page.
Toggle
Click the button to test the relay / output connection.