Control board
ATTACK DP Standard
Wood gasifying boiler "ATTACK DP Standard" is controlled by a boiler and flue gas thermostat.
Description:
1. Reset -
protection of the boiler against overheating (in case the temperature is higher than
110 degrees C, the boiler is disconnected from the power net)
2. Fuse -
protection of the boiler against short circuit
3. Main switch -
switching on of the boiler,switching off if necessary
4. Flue gas thermostat -
5. Boiler thermostat -
6. Thermometer -
7. Pull rod control -
when the temperature of flue gas decreases under set up value, the
fan is switched off
serves for setting up maximum temperature of water in the boiler (after
exceeding set up temperature the fan is switched off and the
boiler works with minimum output. After decreasing set up temperature
the fan is switched on again and the boiler works with maximum
output.
indicates outlet temperature of water from the boiler
serves for opening and closing of fuel cut-off flap
7
1. Reset
2. Fuse
3. Main switch
4. Flue gas thermostat
5. Boiler thermostat
6. Thermometer
7. Pull rod control