3onedata NP308T-8D User Manual page 4

Np308t series 8-port rs-232/485/422 to ethernet serial server

Advertisement

2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements,
and cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond
the groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines.
Cables, power lines and grounding lines cannot be
overlapped and mixed when they are in the same groove
road. When cable is too long, it cannot hold down other
cable, but structure in the middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides
of the cable for maintaining.
【Specification】
Ethernet port
Standard: 10Base-T, 100Base-TX
Protocol: Support TCP, UDP, APR, ICMP and DHCP
Signal: Rx+, Rx-, Tx+, Tx-
Speed: 10/100Mbps
Working: Full-duplex and half duplex
Working mode: Support TCP Server and Client
Transfer distance: 100m
Connector: RJ45
Serial port
Serial port number: 8 ports RS-232 or 8 ports RS-485/422
RS-232 signal: DCD, RXD, TXD, DTR, GND, DSR, RTS, CTS
RS-485 signal: D+, D-
RS-422 signal: T+, T-, R+, R-
Parity bit: None, Even, Odd, Space, Mark
Data bit: 5bit, 6bit, 7bit, 8bit
Stop bit: 1bit, 2bit
Band rate: 300bps~115200bps
RS-232 Transfer distance: no more than 15m
RS-232 connector: RJ45
RS-485 transfer distance: 1200m
RS-485 connector: 5 bits terminal block
Protection: RS-485/422 side, 1.5KV isolation, class 3 static
RS-232 side, class 4 static
LED Indicator
Power: PWR
Working statue indicator: RUN
Ethernet port connect statue: Link
Serial port data indicator: TX1~TX8, RX1~RX8
Power requirements
Input voltage: 9~48VDC
NP308T-8D(RS-232)-P(9~48VDC)
No-load consumption: 0.9W
Full-load consumption: 1.4W
NP308T-8DI(RS-485)-P(9~48VDC)
No-load consumption: 1.8W@12VDC
Full-load consumption: 2.4W@12VDC
Mechanical
Shell: IP30 protection, metal shell
Installation: Wall mounting
NP308T-8D (RS-232)-P(9~48VDC)
Weight: 524g
NP308T-8DI (RS-485)-P(9~48VDC)
Weight: 486g
Size (L×W×H): 160mm×95.5mm×28mm
Environment limits
Working temperature: -40~75℃
Storage temperature: -40~85℃
Relative humidity: 5%~95%(non-condensing)
Standard
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 61000-4-2 (ESD), Level 3
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Warranty
Warranty time: 3 years
Certificates
CE, FCC, RoHS, UL508 (pending)

Advertisement

loading

This manual is also suitable for:

Np308t-8diNp308t-8di-p