Qolsys IQ Panel 2 Image Sensor Installation Guide - ADC-IS-300-LP
PRODUCT SUMMARY & TECHNICAL SPECIFICATIONS
The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in camera designed to capture
images during alarm or non-alarm events when motion is detected.
Product Features:
• Communicates wirelessly to the security control panel
• 35 foot detection range with a 90 degree horizontal FOV
• Configurable PIR sensitivity and pet immunity settings
• Image: VGA 640x480 pixels
• Color Images (except in night vision)
• Night vision image capture with infrared flash (black & white)
• Tamper detection, walk test mode, supervision
• All systems can support up to three Image Sensors
• UL 639 certified
Technical Specifications:
• Alarm.com Model Number: ADC-IS-300-LP
• Interlogix Part Numbers:
• Power Source: Recommended 2 AA 1.5v Energizer Ultimate Lithium Batteries.
• Batteries: Refer to the Batteries section for details
https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Ima
Updated: Tue, 17 Apr 2018 13:46:50 GMT
1

Advertisement

Table of Contents
loading

Summary of Contents for QOLSYS ADC-IS-300-LP

  • Page 1 Qolsys IQ Panel 2 Image Sensor Installation Guide - ADC-IS-300-LP PRODUCT SUMMARY & TECHNICAL SPECIFICATIONS The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in camera designed to capture images during alarm or non-alarm events when motion is detected.
  • Page 2: Hardware Compatibility Requirements - By Panel

    • Operating Temperature Range: 60° to 80°F • Weight: 3.1 oz. (with batteries and without mounting accessories) • Dimensions: 3.1’’ h x 1.8’’ w x 2.3’’ d • Supervisory Interval: 100 minutes (sensor), 3 hours (alarm hardwire) • Wireless Signal Range: Greater than 400 ft open air •...
  • Page 3: Camera Led Reference Chart

    CAMERA LED REFERENCE CHART Camera LED Chart: Refer to this chart to understand the camera LED patterns. https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Ima Updated: Tue, 17 Apr 2018 13:46:50 GMT...
  • Page 4 https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Ima Updated: Tue, 17 Apr 2018 13:46:50 GMT...
  • Page 5: Resetting The Image Sensor

    RESETTING THE IMAGE SENSOR There are two ways to reset the Image Sensor: • Power Cycle – Power Cycle can be done by one of two ways: (1) Take out and reinsert batteries or (2) press and release the sensor reset button. Only initiate a power cycle if the LED has not been active in the last 10 seconds. After a power cycle, the Image Sensor will enter sensor power up state followed by the memory check state.
  • Page 6: Service Plans Requirements

    yellow after the memory check (solid red LED). A network reset will only work if the Image Sensor is not actively communicating with a network. If the Image Sensor is within range of the original panel, it is required that the Image Sensor first be deleted from the panel it was previously learned into before being able to perform a network reset on the Image Sensor.
  • Page 7: Installation: Preparing Panel For Enrollment

    5. Enroll Sensor in Panel – Instructions specific by panel INSTALLATION: ENROLLING IMAGE SENSOR TO PANEL Qolsys IQ Panel / DSCTouch Install Process: Enroll Sensor in Panel - To enroll the sensor on an IQ Panel, follow these steps at the control panel: 1.
  • Page 8 1. Verify if panel has Image Sensor IQ Card by running the Daughter Card Test – Before enrolling any Image Sensors, first run daughter card test (Settings à Advanced Settings à Enter Install code (1-1-1-1 by default) à Systems Tests à Daughter Card Test). Next to Image Sensor press “Run”. The test can take up to a minute before giving the test result.
  • Page 9: Installation: Mounting Image Sensor

    INSTALLATION: MOUNTING IMAGE SENSOR 1. Determine the desired mounting angle – 3 options 2. Screw bracket to back plate. https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Ima Updated: Tue, 17 Apr 2018 13:46:50 GMT...
  • Page 10 3. Determine location to mount sensor. 4. Choose applicable mounting bracket. The sensor hardware packet contains two mounting brackets for different mounting scenarios. Use the provided large screws and anchors to attach the bracket to the wall. (Leave at least 3 inches of clearance above the sensor to allow for battery replacement without uninstalling the mounting https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Ima Updated: Tue, 17 Apr 2018 13:46:50 GMT...
  • Page 11 bracket.) 5. Place sensor with arm on mounting bracket. Adjust the horizontal positioning of the sensor to point towards the desired coverage area. 6. Secure the mounting arm location by sliding lock pin into the hole. Use the washer and remaining small screw to secure the lock pin by screwing upwards through the bottom of the hole in the mounting bracket.
  • Page 12: Deleting Image Sensor From Panel

    1. Verify that rules are confirmed via the dealersite or on MobileTech, Resend rules if they are not confirmed. 2. Verify RF Coverage by checking that the signal strength is above 40%. The signal strength must be greater than 30% for sensor to function properly. 3.
  • Page 13: General Troubleshooting Steps

    Figure 4.Top View: PIR Lens Coverage As indicated in Figure 4, the camera coverage area is narrower than the PIR coverage area. When installing, mount sensor where subjects are likely to be centered in or across PIR and camera field of view. TROUBLESHOOTING General Troubleshooting Steps •...
  • Page 14: False Motion Activations

    sensor closer to control panel, verify signal strength and see if communication resumes. Be sure that Image Sensor daughterboard antenna is correctly routed as indicated in step 5 of the installation procedure. • Replace Batteries: Check battery level at the panel (under “Image Sensor Settings”) and install fresh sensor batteries.

Table of Contents