    FreeStyle Comfort User Controls & System Status Indicators ISO 7000; Graphical symbols for use on Council Directive 93/42/EEC; concerning equipment—Index and synopsis medical devices Read user’s manual before operation. Authorized representative in the Reg. # 1641 European Community This device complies with the...
  • Page 3: Why Your Physician Prescribed Oxygen

    The FreeStyle Comfort is lightweight Although oxygen therapy can be prescribed for enough to be carried via handle, shoulder strap, or users of all ages, the typical oxygen therapy user backpack.
  • Page 4: Front View

    • AC Power Supply • AC Power Cord • DC Power Supply • User Manual Getting to Know Your FreeStyle Comfort Become familiar with the key features of the FreeStyle Comfort and its user interface. Front View User Interface Strap Attachment Oxygen...
  • Page 5 FreeStyle Comfort Top View Display Screen Increase Flow Power Button Decrease Flow Display Screen On Battery Battery Display Flow Setting Battery Percentage Alarm Display Remaining Space Display Screen On AC/DC Power Flow Setting Battery Display Alarm Display Space Charge Indicator...
  • Page 6: Contraindications For Use

    THE PATIENT MIGHT NOT TRIGGER THE CON- WARNING: THE CONCENTRATOR SHOULD BE SERVING FUNCTION. LOCATED AS TO AVOID SMOKE, POLLUTANTS OR WARNING: THE FREESTYLE COMFORT IS NOT FUMES. INTENDED FOR USE WITH A TRACHEOTOMISED PATIENT. WARNING: PREGNANT OR NURSING WOMEN...
  • Page 7 FreeStyle Comfort WARNING: THE USE OF SOME OXY- WARNING: DO NOT ALLOW EITHER THE AIR GEN ADMINISTRATING ACCESSORIES INTAKE OR THE AIR OUTLET EXHAUST TO BE- NOT SPECIFIED FOR THIS OXYGEN COME BLOCKED. DO NOT DROP OR INSERT ANY CONCENTRATOR MAY IMPAIR ITS OBJECTS INTO ANY OPENINGS ON THE DEVICE.
  • Page 8 FreeStyle Comfort CAUTION: In the event of an alarm or WARNING: “NO SMOKING – OXYGEN IN USE” you observe the Oxygen Concentra- SIGNS MUST BE PROMINENTLY DISPLAYED tor is not working properly; consult IN THE HOME, OR WHERE OXYGEN IS IN USE.
  • Page 9 FreeStyle Comfort CAUTION: When using the Oxygen Concentrator Note: Ensure the cannula is fully inserted and in an automobile, boat, or on other DC sources secure. This ensures that the Oxygen Concentrator with the DC power supply, make sure that the can properly detect inspiration for oxygen delivery.
  • Page 10: Specifications

    FreeStyle Comfort Specifications FreeStyle Comfort Dimensions (with Single Battery) 10.0 x 7.3 x 3.1 in (25.4 x 18.5 x 7.9 cm) Dimensions (with Double Battery) 11.0 x 7.3 x 3.1 in (27.9 x 18.5 x 7.9 cm) Weight (with Single Battery Pack) 5 lbs (2.3 kg)
  • Page 11: Operating Instructions

    FreeStyle Comfort Operating Instructions 1. Locate and position the FreeStyle Comfort in a 3. Insert the AC or DC power supply into the proper location for use. power port receptacle on the front, bottom right side of the unit. a. The concentrator should be well-ventilated so that the air intake filters and air outlet are not obstructed.
  • Page 12 FreeStyle Comfort 5. Turn on the FreeStyle Comfort by pressing the Pulse Volume (mL)* power button and select your prescribed flow setting utilizing the increase (+) or decrease (-) Setting flow buttons. Breath Rate 10.5 31.5 52.5 16.8 25.2 33.6 10.5...
  • Page 13: Power Supplies

    Power Supplies REMOVING THE BATTERY Push the battery release button downward away The FreeStyle Comfort can be powered in 3 ways: from the FreeStyle Comfort. While HOLDING this • Rechargeable Battery Pack button, slide the battery out by pulling it away from •...
  • Page 14: Initial Charging

    To check the battery charge when it is not installed a new battery pack. Battery pack durations will in the FreeStyle Comfort, lay it flat and press the remain constant regardless of your breath rate. TEST button. The battery gauge indicator lights...
  • Page 15: Ac & Dc Power Supply

    PACK INSTALLED IN THE OXYGEN CONCENTRATOR. 3. Connect the opposite end of the AC power cord To connect the FreeStyle Comfort to AC Power: to the wall or other appropriate electrical outlet. 1. Connect the AC power brick to the power connector inlet on the front, right bottom of the FreeStyle Comfort.
  • Page 16 FreeStyle Comfort 4. Turn on the FreeStyle Comfort by pressing the 3. Connect the opposite end of the DC power cord power button and select your prescribed flow to the automobile or other DC accessory outlet. setting utilizing the increase (+) or decrease (-) flow buttons.
  • Page 17: Cleaning, Care & Routine Maintenance

    Cleaning, Care & Routine Maintenance ROUTINE MAINTENANCE Servicing of internal components inside of the cabi- net of the FreeStyle Comfort must be performed by the oxygen provider. The operator of the unit is responsible for the following maintenance procedures. 2. Wash both filters in a warm solution of soap and •...
  • Page 18: Cannula Replacement

    FreeStyle Comfort avoid conditions that can create condensation such WARNING: USE A DAMP (NOT WET) CLOTH OR as rapid fluctuations in the ambient temperature. SPONGE TO CLEAN THE BATTERY PACK. FIRST SPRAY THE CLOTH OR SPONGE WITH A MILD For storage of a month or more, a discharged or...
  • Page 19: Alarm Conditions

    FreeStyle Comfort Alarm Conditions Priority # Alarm Display Audible More Details Description Signal System 1 beep Unit will alarm when battery tempera- Malfunction every 20 ture is approaching saftey shutdown Battery Over threshold. Temp If shutdown threshold is reached, unit will shut down.
  • Page 20 FreeStyle Comfort Priority # Alarm Display Audible More Details Description Signal System 1 beep Malfunction every 30 Flow Rate (OCD Valve Failure, Obstruction of Gas Pathway) Low Battery 1 beep, Warning repeat Breathing 1 beep Breathing Rate exceeds 40 bpm...
  • Page 21 Info Plug in none external power in the run condition Info Unplug 1 info Display CAIRE screen for 2 seconds and external beep then turn display off. power in the off Condition Info Unplug 1 info external beep...
  • Page 22 FreeStyle Comfort Priority # Alarm Display Audible More Details Description Signal Info In Standby none Screen will display for 5 sec then turn off Mode - when up or down button is pressed display shows battery and charging state Info...
  • Page 23: Troubleshooting

    FreeStyle Comfort Troubleshooting Problem Probable Cause Solution FreeStyle Comfort displays Refer to Alarm Conditions Refer to Alarm Conditions table. alarm and produces inter- table. mittent beep. Oxygen concentrator does Battery is discharged. Power the unit through the AC or DC outlet.
  • Page 24: Travel Information

    FreeStyle Comfort Travel Information ACTIVATE AIRPLANE MODE Battery Power The FreeStyle Comfort is FAA-approved for use POC can be used on an aircraft per normal operat- on-board commercial aircraft. Prior to any travel ing procedures using Battery Power ONLY, when (airline, train, cruise, etc.) you should:...
  • Page 25: Shoulder Strap Installation

    2. Clip strap onto the ring on the unit or bag. are needed for order. Carrying Bag Instructions To insert and secure your FreeStyle Comfort in the carrying bag, utilize the following instructions. PN MN232 C | User Manual ENG - 25...
  • Page 26: Weee And Rohs

    EMC Testing Guidance and Manufacturer’s Declaration —Electromagnetic Emissions The FreeStyle Comfort is intended for use in the electromagnetic environment specified below. The customer or the user of the FreeStyle Comfort should assure that it is used in such an environment.
  • Page 27: Guidance And Manufacturer's Declaration-Electromagnetic Immunity

    FreeStyle Comfort Guidance and Manufacturer’s Declaration—Electromagnetic Immunity The FreeStyle Comfort is intended for use in the electromagnetic environment specified below. The customer or the user of the FreeStyle Comfort should assure that it is used in such an environment. Immunity test...
  • Page 28 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the FreeStyle Comfort is used exceeds the applicable RF compliance level above, the FreeStyle Comfort should be observed to verify normal operation.
  • Page 29 Recommended separation distances between portable and mobile RF communications equipment and the FreeStyle Comfort The FreeStyle Comfort is intended for use in an electromagnetic environment in which radiated RF distur- bances are controlled. The customer or the user of the FreeStyle Comfort can help prevent electromagnetic...
  • Page 30 FreeStyle Comfort Notes 30 - ENG PN MN232 C | User Manual...
  • Page 31 FreeStyle Comfort Notes PN MN232 C | User Manual ENG - 31...
  • Page 32 Tel: +49 (0) 6442-962073 E-mail: info@mps-gmbh.eu Worldwide: www.CAIREmedical.com Copyright © 2018 Chart Industries. CAIRE Inc. reserves the right to discontinue its products, or change the prices, materials, equipment, quality, descriptions, |MN232-C_~ specifications and/or processes to its products at any time without prior notice and with no further obligation or consequence.