Power Supply For The Itnc 530 - HEIDENHAIN iTNC 530 Technical Manual

Cnc control
Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

3.5 Power Supply for the iTNC 530

3 – 12
The UV 1x0 or the UV 105 power supply unit supplies the iTNC 530 with
power.
Power is supplied through X69 and, with the UV 105, in addition through a 5 V
terminal on the CC 422.
For information on the UV 1x0 supply units, refer to the Technical
Manual "Inverter Systems and Motors."
Whether the UV 1x0 supply unit is sufficient or whether a UV 105 is needed
as additional equipment, depends on the current consumption of the used
units.
Device
UV 1x0, UE 2xx B
UV 105
Device
MC 422
CC 422/6 control loops
CC 422/10 control loops
LS, LB
ERN, ROD, RON
ECN, EQN, ROC, ROQ, RCN 0.25 A (+0.085 A with line drop
LC 181
a. For cable lengths > 10 m between the logic unit and the encoders
with EnDat interfaces, a line drop compensator is required
(efficiency = 75 %).
Example:
Device
MC 422
CC 422/6 control loops
3 x LS for X, Y, Z
3 x ERN for X, Y, Z
1 x ERN for spindle
2 x ROD for B, C
2 x ERN for B,C
Total
For this application, an UV 105 is not needed.
Load capacity
8.50 A
20.00 A
Current consumption
4.80 A
1.50 A
3.00 A
0.15 A
0.20 A
a
compensator)
0.30 A (+0.085 A with line drop
a
compensator)
Current consumption
4.80 A
1.50 A
0.45 A
0.6 A
0.2 A
0.4 A
0.4 A
8.35 A < 8.50 A
HEIDENHAIN Technical Manual iTNC 530

Advertisement

Table of Contents
loading

Table of Contents