3.9.1

Reset through Binary Input

In the INPUT MATRIX configuration, LEDs and outputs can be reset by configuring the binary input. The
configuration can be executed with ReyDisp Evolution or Human Machine Interface (HMI).
3.9.2

Reset using Reydisp Software

When the relay is latched, LEDs can be reset by sending an appropriate command over the data communications
channels using Reydisp software.
In the Reydisp Evolution screen, navigate to Relay > Control and click Reset Flags.
3.9.3
TEST/RESET► Key
From the Relay Identifier Screen, reset the LEDs and outputs by pressing the TEST/RESET► key.
3.9.4

Reset through rear communication protocol

The resetting of LEDs and BOs can be possible via the rear communication protocol like Modbus and
IEC 60870-5-103.