Maintenance - Cembre LD-16B Operation And Maintenance Instruction Manual

Rail drill
Table of Contents

Advertisement

Before servicing or maintenance the drill, always remove the battery.
After fi rst 10 operating hours, proceed with sump oil change,
as follows:
Remove oil fi ller cap (07).
Remove the cap with the magnetic insert (21).
Make sure that all the oil comes out by slightly tilting the drill.
Clean up the cap (21) (see § 16.1.3).
Reassemble the cap (21).
Fill the sump with oil to the level indicator (see § 16.1.2) using the
oil supplied (100 ml) in the ACCESSORIES KIT of the rail drill.
Replace the fi ller cap (07).
Ensure that disposal of used oil is in accordance with current
legislation.
Daily maintenance is indispensable to keep the machine in best
condition. Maintenance not carried out properly, or carried out by
unauthorised or unqualifi ed personnel can noticeably reduce the ma-
chine's effi ciency and increase the risk of accidents and serious injury.
The maintenance procedures described may be carried out by the
operator.
For any eventual fi ne tuning or repairs, return to Cembre (Ref. to § 17).
16.1) ORDINARY MAINTENANCE OF THE DRILL
Daily
Before use, check:
The drill in its entirety (securing of various components).
The correct operation and integrity of the Motor switch (Ref. to § 5).
The integrity and charge of the batteries.
After use:
Clean the machine of any contaminants and swarf by using a clean rag.
Thoroughly clean the spindle area and the drilling machine of any swarf.
Clean the air intake on the side of the motor if it is clogged.
33

16. MAINTENANCE

07
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ld-16baLd-16btLd-16be