Carrier R080-528 Installation Instructions Manual page 54

Air-cooled chillers, 60 hz
Table of Contents

Advertisement

UNIT VOLTAGE
UNIT
Supplied
V-Hz
30GXN,R
(3 Ph)
Min
208/230-60
187
230-60
207
460-60
414
080
575-60
518
380-60
342
208/230-60
187
230-60
207
083
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
090
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
093
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
460-60
414
106
575-60
518
380-60
342
208/230-60
187
230-60
207
108
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
114
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
118
460-60
414
575-60
518
380-60
342
208/230-60
187
230-60
207
460-60
414
125
575-60
518
380-60
342
LEGEND
ICF
— Maximum Instantaneous Current Flow
— Minimum Circuit Ampacity (for wire sizing)
MCA
MOCP
— Maximum Overcurrent Protection
Rec Fuse Size — Recommended Dual-Element Fuse Amps (150% of largest
compressor rated load amps [RLA] plus 100% of remaining
compressor RLAs and sum of condenser fan full load amps
[FLAs]. Choose next largest standard fuse size.)
WD
— Wye-Delta Start
XL
— Across-the-Line Start
*Wye-delta start is standard. Across-the-line start is not available.
NOTES:
1. Main power must be supplied from a field-supplied fused electrical service with a
(factory or field-installed) disconnect located in sight from the unit.
2. Cooler heater, oil heater, and control circuit power must be supplied from a separate
source through a field-supplied disconnect. The control circuit power transformer acces-
sory may be applied to power from the main unit power supply.
3. Maximum incoming wire size for each terminal block is 500 kcmil.
4. Maximum allowable supply voltage phase imbalance is voltage 2%.
5. Never operate a motor where a phase imbalance in supply voltage is greater than 2%.
Use the following formula to determine the percent voltage imbalance.
Percent Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 240-3-60.
AB = 243 v
BC = 236 v
AC = 238 v
Average voltage =
=
Table 7A — Electrical Data Reduced Ambient 115 F Data
POWER
SUPPLY
# Power Supply
QTY. REQD
Conductors
Max
253
1
3
253
1
3
506
1
3
633
1
3
418
1
3
253
1
3
253
1
3
506
1
3
633
1
3
418
1
3
253
1
6
253
1
3
506
1
3
633
1
3
418
1
3
253
1
6
253
1
3
506
1
3
633
1
3
418
1
3
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
253
1
6
253
1
6
506
1
3
633
1
3
418
1
3
243 + 236 + 238
3
239 v
STANDARD CONDENSER FAN
ICF
MCA
MOCP
XL
WD
356.5
500
*
527.9
324.5
450
*
515.1
160.9
225
652.6
255.6
129.0
175
542.4
205.4
195.6
250
729.3
291.3
353.7
500
*
534.5
324.4
450
*
522.9
160.1
225
655.8
258.8
128.0
175
544.6
207.6
193.7
250
732.7
294.7
406.1
600
*
593.9
369.3
500
*
581.1
183.2
250
757.6
288.6
148.1
200
606.4
231.4
222.9
300
845.3
327.3
389.1
500
*
600.5
356.4
500
*
588.9
176.1
250
760.8
291.8
140.8
200
608.6
233.6
213.0
300
848.7
330.7
482.0
700
*
693.9
438.9
600
*
681.1
217.3
300
899.4
338.4
174.4
250
719.8
270.8
264.9
350
1002.5
382.5
445.8
600
*
705.2
407.7
500
*
691.7
201.7
250
904.7
343.7
161.4
225
723.8
274.8
244.1
350
1008.5
388.5
507.7
700
*
719.6
462.0
600
*
704.2
228.9
300
911.0
350.0
183.4
250
728.8
279.8
279.0
400
1016.6
396.6
486.0
600
*
745.5
445.6
600
*
729.6
219.9
300
922.9
361.9
175.9
250
738.3
289.3
266.1
350
1030.5
410.5
576.6
800
*
814.6
525.4
700
*
795.4
260.6
350
1025.1
396.1
207.8
300
820.3
317.3
316.1
450
1145.6
449.6
Determine maximum deviation from average voltage:
(AB) 243 – 239 = 4 v
(BC) 239 – 236 = 3 v
(AC) 239 – 238 = 1 v
Maximum deviation is 4 v. Determine percent voltage imbalance:
% Voltage Imbalance
This amount of phase imbalance is satisfactory as it is below the maximum allow-
able 2%.
IMPORTANT: Contact your local electric utility company immediately if the supply
voltage phase imbalance is more than 2%.
54
CONTROL CIRCUIT
Rec Fuse Size
V-Hz
(Single Ph)
XL
WD
*
400
115-60
*
400
115-60
200
200
115-60
150
150
115-60
225
225
230-60
*
400
115-60
*
400
115-60
200
200
115-60
150
150
115-60
225
225
230-60
*
500
115-60
*
450
115-60
225
225
115-60
175
175
115-60
250
250
230-60
*
450
115-60
*
400
115-60
200
200
115-60
175
175
115-60
250
250
230-60
*
600
115-60
*
500
115-60
250
250
115-60
200
200
115-60
300
300
230-60
*
500
115-60
*
500
115-60
250
250
115-60
200
200
115-60
300
300
230-60
*
600
115-60
*
600
115-60
300
300
115-60
225
225
115-60
350
350
230-60
*
600
115-60
*
500
115-60
250
250
115-60
200
200
115-60
300
300
230-60
*
700
115-60
*
600
115-60
300
300
115-60
250
250
115-60
400
400
230-60
4
= 100 x
239
= 1.7%
MCA and MOCP
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15
30
30
30
30
15