Master/Slave Connectivity; Remote Device Management (Rdm); Dimmer Modes - Chauvet OVATION FD-205WW User Manual

Table of Contents

Advertisement

S
ETUP

Remote Device Management (RDM)

Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate
bi-directionally along existing DMX cabling. Check the DMX controller's User Manual or with the
manufacturer as not all DMX controllers have this capability. The Ovation FD-205WW supports RDM
protocol that allows feedback to make changes to menu map options.

Master/Slave Connectivity

The Master/Slave mode allows a Ovation FD-205WW (the master) to control one or more Ovation FD-
205WW products (the slaves) without a DMX controller. One Ovation FD-205WW becomes the master
when running an auto or custom program, or by being in a Static mode.
You must configure each slave's control panel to operate in Slave mode. During Master/Slave operation,
the slaves will operate in unison with the master.
DO NOT connect a DMX controller to products operating in Master/Slave mode. The
DMX controller signals may interfere with the signals from the master.
The
configure the master and slaves.
If you are not familiar with DMX standards or Master/Slave connectivity,
download the DMX Primer from the Chauvet website
www.chauvetprofessional.com

Dimmer Modes

The Ovation FD-205WW may be plugged into and controlled using a regular dimmer.
When in SENS mode, advanced onboard electronics automatically detect what type of power and
data the product receives and it responds accordingly. This is the factory default setting.
When in DMX mode, the product runs only on constant power and is controlled solely on DMX. The
product will not respond to dimmer control in this mode.
When in DMMR mode, DMX control is turned off. Intensity is controlled using a dimmer. In this
mode, the product reacts exactly like an incandescent product.
For the best performance while running on dimmers, use the settings listed below:
1.
Go to the SETTING main level.
2.
Select the DIMMER programming level.
3.
Select DIM4.
4.
Go back to SETTING main level.
5.
Select the CURVE programming level.
6.
Select CURVE3.
Ovation FD-205WW User Manual Rev. 1
Operation
section of this manual provides detailed instructions on how to
for more information.