Center Signal Strength
Select the Center Signal Strength option to display the
Signal Strength in the center of the screen� The Center
Signal Strength option makes the Signal Strength easier
to see when locating using Signal Strength alone�
Note: The Center Signal Strength option is disabled by
default. Refer to the Customizing Display Elements sec-
tion for instructions on how to enable the Center Signal
Strength option.
30 – English
Signal Focus Control
Signal Focus Control acts as a magnifying glass on the
signal� It narrows the sample bandwidth and displays
more stable incoming signals, allowing the SR‑24 to
focus on a particular signal with increased detail�
Note: The selection of a narrow bandwidth increases the
detection distance and precision, but slows the refresh
rate of the display. As a result, when using the narrow-
est setting, move the SR-24 along the line more slowly.
The Signal Focus Control is disabled by default and must
be enabled in the Display Settings screen to make any
adjustments to it�
When the Signal Focus Control is activated, from the
Active View Area, use the Up and Down Arrow Keys
to set it to one of the following bandwidths:
• 4 Hz, wide (default setting when the Signal Focus
Control is disabled)
• 2 Hz
• 1 Hz
• 0�5 Hz
• 0�25 Hz, narrow
Signal Focus
Control
Note: The Signal Focus Control option is disabled by
default. Refer to the Customizing Display Elements sec-
tion for instructions on how to enable the Signal Focus
Control option.