Class 0X05 Instance 2 Attribute (Polled I/O Connection) - Mitsubishi Electric FR-A7ND Instruction Manual

Inverter plug-in option devicenet communication function 700 series
Hide thumbs Also See for FR-A7ND:
Table of Contents

Advertisement

7.4.2

Class 0x05 Instance 2 Attribute (Polled I/O connection)

Class 0x05 Instance 2
Attribute ID
Access
1
Get
2
Get
3
Get
4
Get
5
Get
6
Get
7
Get
8
Get
Name
State
Instance Type
Transport Trigger Class
00 to 0xFF
Produced Connection
0 to 0xFFFF
ID
Consumed Connection
0 to 0xFFFF
ID
Initial Command
00 to 0xFF
Characteristics
Produced Connection
0 to 0xFFFF
Size
Consumed Connection
0 to 0xFFFF
Size
Range
00
Non-existent
01
Configuring
03
Established
04
Timed out
01
Polled I/Oconnection
0x82: Server Transport Class 2
(Example) 0x03C0
Group 1 Polled I/O response mesagge of Slave
Source MAC ID = 0
The value to be placed in the CAN Identifier Field when
this connection transmits
(Example) 0x0405
Group 2 Polled I/O command message of Master
Destination MAC ID = 0
The value distinguishes the receive messages.
The value will be specified in the CAN Identifier Field of
messages that are to be consumed.
Source: Group 1 Message
Destination: Group 2 Message
Maximum amount of I/O data transmittable
4: Assembly Instance 70,71
6: Assembly Instance 176
Maximum amount of I/O data receivable
4: Assembly Instance 20,21
6: Assembly Instance 126
OBJECT MAP
Definition
7
51

Advertisement

Table of Contents
loading

Table of Contents