Class 0X01 Instance 1 - Mitsubishi Electric FR-A7ND Instruction Manual

Inverter plug-in option devicenet communication function 700 series
Hide thumbs Also See for FR-A7ND:
Table of Contents

Advertisement

OBJECT MAP
7.1.2

Class 0x01 Instance 1

(1) Attribute
Attribute ID
Access
1
2
3
4
5
6
7
*1
High byte of hexadecimal word data means integer and low byte means decimal.
For example, when the read data is 0x010A, it means version 1.010.
*2
Bit definition
Bit 0: 0 = allocated, 1 = not allocated, Bit 2: 0, Bit 2: 1 = minor fault occurrence, Bit 9: 0, Bit 10: 1 = LED is
flickering red, Bit 11: 1 = LED is lit red
*3
The actual data are 0x04, 0x46, 0x37, 0x30, 0x30. 0x04 means 4 byte data and the rest means ASCII code of
"F700".
(2) Service
Service Code
Symbol
0x05
0x0E
* As set in Pr. 75. Refer to the inverter manual for details of Pr. 75.
38
Definition
Get
Vendor ID (Mitsubishi electric)
Get
Device Type (AC drive)
Get
Product Code
Get
Revision
Get
Status
Get
Serial Number
Get
Product Name (FR-F700)
Name
Reset
Reset *
Get
Get_Attribute_Single
Data
Length
Word
Word
Word
Struct
Word
Double
Word
5 Byte
Setting Range
0
Inverter reset
1
Parameter all clear and inverter reset
Get Attribute Single
Attribute Value
161
02
703
1.YYY
*1
*2
xxxxxxxx
F700
*3
Description

Advertisement

Table of Contents
loading

Table of Contents