Watt Stopper DSW-301 Installation Instructions Manual

Dual technology multi-way wall switch occupancy sensors

Advertisement

Quick Links

DSW-301

Specifications

Voltages:
DSW-301 & DSW-302. . . . . . . . . . . . . .120/277VAC, 50/60Hz
DSW-301-347 & DSW-302-347 . . . . . . . . ..347VAC, 50/60Hz
Load Limits for relay 1:
@120VAC . .1000W tungsten, ballast, E-ballast, LED, 1/4 HP
@277VAC. . . . . . . . . 1200W ballast, E- ballast, LED, 1/4 HP
@347VAC . . . . . . . . . . . . . . . . . . 1500W ballast, LED, 1/4 HP
Load Limits for relay 2:
@120VAC . . .800W tungsten, ballast, E-ballast, LED, 1/6 HP
@277VAC . . . . . . . . . 1200W ballast, E-ballast, LED, 1/6 HP
@347VAC . . . . . . . . . . . . . . . . . . 1500W ballast, LED, 1/6 HP
Time Delay Adjustment . . . . . . . . . . . . . . . . . . . .5 to 30 minutes
Walk-Through Mode . . . . 3 minutes if no activity after 30 sec.
Test Mode . . . . . . . . . . . . . . . . . 10 min. with 5 sec. time delay
PIR Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .High or Low
Ultrasonic Adjustment . . . . . . . . . . . Minimum to Maximum, Off
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40kHz
Light Level Adjustment . . . . . . . . . . . . . . . . . . . . . . 8fc to 180+fc
Alerts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selectable Audible
Optional Neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . .All models
Multi-Way Capability . . . . . . . . . . . . . . . . . . . . . . . . ..All models
Terminal screw torque . . . . . . . . . . . . . . . 16 lbf-in (18 kgf-cm)
DSW-301/DSW-301-347
DSW-302/DSW-302-347
Dual Technology Multi-Way Wall Switch
DSW-301-347
Occupancy Sensors
DSW-302
DSW-302-347
Santa Clara, CA 95050
800.879.8585

Advertisement

Table of Contents
loading

Summary of Contents for Watt Stopper DSW-301

  • Page 1: Specifications

    DSW-301 Specifications Voltages: DSW-301 & DSW-302....120/277VAC, 50/60Hz DSW-301-347 & DSW-302-347 ..347VAC, 50/60Hz Load Limits for relay 1: @120VAC . .1000W tungsten, ballast, E-ballast, LED, 1/4 HP @277VAC.
  • Page 2: Time Delay 1

    Time Delays The DSW sensor holds the load ON until no motion is detected for the selected time delay. Select the time delay using DIP switch settings. In the DSW-302, both relays use the same delay. Test/20 min A Test Mode with a short time delay of five seconds is set when DIP switches 1 &...
  • Page 3: Trigger Mode Standard

    Trigger Mode The DSW sensor has four occupancy trigger options, set with DIP switches 5 and 6. Determine the appropriate option using the Trigger matrix. In the Trigger Mode DIP switch setting table, in order to deem the area occupied: • Both requires motion detection by the PIR and the Ultrasonic.
  • Page 4 There is a delay due to initialpower-up of the Neutral Green (optional) sensor that only occurs during installation. Ground Neutral 5. Test and adjust the sensor DSW-301 and DSW-301-347 Wiring Neutral Black Primary Line 1 Black Primary Line Load Blue...
  • Page 5 The time delay for all units is defined by the unit with the smallest time delay Line Black Black Load Yellow Yellow traveler Green Green Neutral Neutral Green Green (optional) (optional) Ground Ground Neutral Typical wiring (DSW-301 or DSW-301-347 - up to 4 sensors)
  • Page 6 Sensor Operating Modes Sensor #1 Sensor #2 Light Fixture Auto-ON Auto-ON The load turns ON and OFF automatically based on occupancy detection by either one of the sensors. The sensors keep the load ON until no motion is detected and will use the time delay of the sensor with the lowest value.
  • Page 7 Line Black Primary Black Load Blue Blue Yellow Brown Secondary Brown Green Green Load Green Green Neutral Neutral (optional) (optional) Ground Ground Neutral Bi-level wiring (DSW-302 and DSW-302-347 - up to 4 sensors) Note: Button 1 on any sensor controls load #1 and button 2 on any sensor controls load #2. Neutral Line 1 Line 2...
  • Page 8: Manual On

    A “walk-through” mode can turn lights off after only 3 minutes if no activity is detected after 30 seconds following an occupancy detection. The DSW-301 has one relay and one ON/OFF button. The DSW-302 contains two relays and two ON/OFF buttons to allow control of one or two loads independently. Pressing a button toggles the state of the corresponding relay.
  • Page 9: Table Of Contents

    DIP Switches Tabs Ultrasonic Cones Detection LEDs Button Red = PIR Hinges Green = Ultrasonic DSW-302 shown. DSW-301 has a PIR Lens single button and the Ultrasonic sensitivity adjustment trimpot is in a slightly different position. Call 800.879.8585 for Technical Support...
  • Page 10: Factory Settings

    ADJUSTMENTS Sensor Adjustment Remove the wall plate. Remove the button cap by firmly squeezing together the top sides of the button assembly. Gently pull it away from the unit. When the adjustments are completed, replace the button cap by inserting its hinges into the tabs on the main unit and then squeeze the top of the button while pressing it into the unit.
  • Page 11 Lights do not turn OFF 1. There can be up to a 30 minute time delay after the last motion is detected. To verify proper operation, set DIP switch 1 to ON, then reset switches 1 and 2 to OFF to start Test Mode. Move out of view of the sensor.
  • Page 12: Warranty Information

    WARRANTY INFORMATION WattStopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of WattStopper for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation or reinstallation.

This manual is also suitable for:

Dsw-301-347Dsw-302Dsw-302-347

Table of Contents