Turn Rate Limit; Off Course Angle; Powersteer - Raymarine SmartPilot X-5R Drive Installation & Setup

Helm mount fixed pilot
Table of Contents

Advertisement

58
Screen Text
RESPONSE

Turn rate limit

This limits your boat's rate of turn under SPX-5R Drive system control.
Screen Text
TURN RATE

Off course angle

This screen determines the angle used by the OFF COURSE alarm (see your
Operating Guide). The OFF COURSE alarm operates if the pilot strays off course by
more than the specified angle for more than 20 seconds.
Screen Text
OFF COURSE

PowerSteer

If you have a joystick connected to your SPX-5R Drive system, use this screen to
select the required joystick mode of operation. For detailed operating information,
refer to the guide supplied with the joystick.
SmartPilot X-5R Drive Installation and Setup Guide
Options
Range = 1 to 9
Levels 1 to 3 minimize the amount of pilot activity. This conserves
power, but may compromise short-term course-keeping accuracy.
Levels 4 to 6 should give good course keeping with crisp, well con-
trolled turns under normal operating conditions.
Levels 7 to 9 give the tightest course keeping and greatest rudder
activity (and power consumption). This can lead to a rough passage
in open waters as the SPX-5R Drive system may 'fight' the sea.
Range
1° to 30° per second in 1° steps
Range
15° to 40° in 1° steps
Locked heading
15˚ minimum
Boat heading
D3264-3