64
Environmental conditions:
• operating temperature
• storage temperature
• relative humidity limit
• water protection
Inputs
Steering load:
• Maximum continuous
• Maximum instantaneous
Manual steering torque
Servicing
CE compliance and approvals
SmartPilot X-5R Drive Installation and Setup Guide
-10°C to 50°C (14°F to 122°F)
-20°C to 65°C (-4°F to 149°F)
95% Relative Humidity (non condensing)
water ingress protection to IPX6, when mounted vertically
Drive power from compatible Course Computer.
5 pound feet (7 Newton meters)
11 pound feet (15 Newton meters)
2 pound feet (3 Newton meters)
Daily inspection before commencing any passage:
- Visually inspect the Drive installation.
- Check autopilot operation.
Annual inspection:
Check once per year that the Drive, and associated torque
restraint are securely fitted and have not worked loose during
usage.
Remove any deposits from the emergency release pin and
check its operation.
Service interval:
Inspect and service in line with your steering system manufac-
turer recommendations.
In any event a Raymarine approved service must be carried out
every 2 years or 200 engine hours, whichever occurs soonest.
2004/108/EC (EMC).
EN29775 Section 7.2.2 Helm assembly tests.
BSEN28848 Helm impact test.
Australia and New Zealand: C-Tick, Compliance Level 2.