ECG1200G Electrocardiograph - User Manual

Chapter4 Product Main Characteristics

4.1 Display with 800*600 dots color LCD, operate either by buttons or touch screen, which is
convenient and quick.
4.2 With high resolution thermal print system (8 dots/mm), it needs no adjustment, and the
record frequency is up to 150Hz.
4.3 Real-time and continuously record clear and exact 12 channel ECG waveforms and remarks.
The remarks include lead sign, sensitivity, paper speed and filter state,etc.
4.4 In auto mode, one button operation to complete record, which will improve work efficiency.
4.5 Full digital filter design, against baseline draft, AC and EMG interference.
4.6 Baseline auto adjusted, optimized print setup, selectable rhythm lead.
4.7 Full touch keyboard control makes operations more convenient and the device status are
clear and easily read through LCD screen.
4.8 The device can be powered either by AC or DC, with built-in lithium rechargeable battery
and auto protection circuit, without operation, auto powering off time can be set up.
4.9 This device can record 300 pieces of ECG and print 180 minutes continually in the best DC
state.
4.10 This device can store more than 1000 cases, more convenient for data review and statistic.
4.11 The figure of whole device is elegant and gliding.
4.12 One button operation to complete printing and storing.
4.13 The device adopts digital signal processor, through AC, DFT and EMG filters to obtain
electrocardiogram of high quality.
4.14 The device has such functions as measuring, analysing and diagnosing conventional ECG
parameters automatically to reduce doctor's burden and improve work efficiency.
4.15 The device gathers 12-channel ECG signals synchronously and then analyses record modes
of such channels as 12*1, 6*2+1, 6*2, rhythm row12, row10, row8, row6,etc, with multiply
report formats.
4.16 With multiply lead display modes, the device can observe 3,6,or 12 lead real-time
waveforms, and display such information as lead-off and printer paper lack, etc, also with ECG
parameter auto-detected and analysis reports, and record waveforms in auto/manual mode, with
database to store patient information.
4.17 Safety Classification: Class I, defibrillator-proof type CF applied part .
4.18 The degree of protection against entry liquids: IPX0.
4.19 According to the degree of safety of application in the presence of a flammable anaesthetic
mixture with air: Equipment not suitable for use in the presence of the gas above.
4.20 According to the mode of operation: Continuous operation.
4.21 Explanation of some symbols in this device:
~AC
AC work mode
OFF
Power supply is disconnected
ON
Power supply is connected
Equipotential grounding post
Refer to instruction manual/booklet
Type CF applied part with defibrillation protection function
RS232 I/O
USB port