Contec CMS-60C User Manual

Contec CMS-60C User Manual

Contec cms-60c pulse oximeter
Hide thumbs Also See for CMS-60C:

Advertisement

Pulse
Oximeter
Pulse Oximeter
Pulse
Oximeter
I

Advertisement

Table of Contents
loading

Summary of Contents for Contec CMS-60C

  • Page 1 Pulse Oximeter Pulse Pulse Oximeter Oximeter...
  • Page 2 Instructions Instructions to to to User User Instructions User Dear users, thank you very much for purchasing the Pulse Oximeter. This Manual is written and compiled in accordance with the council directive MDD93/42/EEC for medical devices and harmonized standards. In case of modifications and software upgrades, the information contained in this document is subject to change without notice.
  • Page 3: Table Of Contents

    C C C ontents ontents ontents 1Safety 1Safety 1Safety..............................................................................................1 1 1 1.1Instructionsforsafeoperations........................1 1.2Warning..............................1 1.3Attention...............................
  • Page 4: Instructionsforsafeoperations

    1 1 1 Safety Safety Safety Instructions safe operations 1.1 Instructions Instructions for for safe safe operations operations  Check the main unit and all accessories periodically to make sure that there is no visible damage that may affect patient’s safety and monitoring performance about cables and transducers. It is recommended that the device should be inspected once a week at least.
  • Page 5: Features

    individual pulse rate.  Please read the measured value when the waveform on screen is equably and steady-going, This measured value is optimal value. And the waveform at the monment is the standard one.  If some abnormal conditions appear on the screen during test process, pull out the finger and reinsert to restore normal use.
  • Page 6: Environmentrequirements

    Environment requirements 2.3 Environment Environment requirements requirements Storage Environment a) Temperature :-40℃~+60℃ b) Relative humidity :5%~95% c) Atmospheric pressure :500hPa~1060hPa Operating Environment a) Temperature:0℃~50℃ b) Relative Humidity :15%~95% c) Atmospheric pressure:700hPa~1060hPa 3. 3. 3. Principle Principle Principle Principle of the Oximeter is as follows: An experience formula of data process is established taking use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive Hemoglobin (Hb) and Oxyhemoglobin (HbO ) in glow &...
  • Page 7: Mainparameters

    Main Parameters 4.2 Main Main Parameters Parameters A. A. A. Measurement Measurement Measurement of of of SpO 2 2 2 Measuring range: 0%~100% Accuracy: When the SpO measuring range is 70%~100%,the permission of absolute error is ±2%; below 70% unspecified B.
  • Page 8: Accessories

    Accessories 5.2 Accessories Accessories A. A. A. A lithium battery B. B. B. A User Manual C. C. C. A power adapter D. D. D. A data line E. E. E. A disk (PC software) F. F. F. An oximeter probe 6 6 6 Operating Operating Operating Guide...
  • Page 9 a) a) a) Alarm including the alarm of measure data's going beyond the limits, the alarm of low-voltage, the alarm of probe or finger's out of position. b) b) b) When alarm is on,press the"alarm pause button"can pause the alarm,it can renew alarm in about 60s,and if pressing the"alarm pause button"...
  • Page 10 Figure 6. b. b. b. The The a a a larm larm larm state state state setting setting setting Press the"up button"or"down button",move the menu choice bar to "Alarm",then choose the alarm state (on/off) by pressing the "menu button", choose “on”to start the alarm function, and choose “off” to close it for good.
  • Page 11 next place after setting.When the black cursor move to"Yes"(store) or "No"(don't store),press the"up button"or"down button"to choose setting,then press the"menu button"to confirm setting. c. c. c. When the"Stop"is displayed on menu,the"Do you really want to stop recording"dialog box will be displayed when pressing the "menu button".then press the"up button"or"down button"to choose setting,then press the"menu button"to confirm setting.
  • Page 12 Review"icon to start the program. b. b. b. On the main menu interface,press the"up button"or"down button" in order to move the menu choice bar to"Upload",then press the"menu button"to transmit the stored data to computer for replay and analysis. c. c. c. In the state of storing, it is not applicable for the users to upload the stored date to computer. d.
  • Page 13: Attentionforoperation

    d d d ) When charging the battery in the state of power off, the sign of battery status still exists on the screen, but it will disappear in about 60 seconds for saving power. However, the sign will appear again if you press any button(power on/off excluded) at this moment.
  • Page 14: Transportationandstorage

    B. B. B. Please recharge the battery when the screen shows C. C. C. Recharge the battery soon after the over-discharge. The device should be recharged every six months when it is no regular used. It can extend the battery life following this guidance. D.
  • Page 15 9 9 9 Key Key of of of Symbols Symbols Symbols Signal Description Warning – See User Manual The pulse oxygen saturation(%) Pulse rate (bpm) Close the alarm sound indication Open the alarm sound indication Close the pulse sound indication Open the pulse sound indication Power on/off button Alarm pause button/up button...
  • Page 16 10 10 10 Function Function Specification Function Specification Specification Information Information Information Display Display Display Mode Mode Mode ) The Pulse Oxygen Saturation(SpO 2-digit digital OLED display Pulse Rate(PR) 3-digit digital OLED display Pulse Intensity (bar-graph) bar-graph OLED display Parameter Specification Parameter Parameter Specification...