Connecting Alarm Circuits - Cisco ISA3000-4C-K9 Hardware Installation Manual

Hide thumbs Also See for ISA3000-4C-K9:
Table of Contents

Advertisement

Connecting Alarm Circuits

LED
Alarm Out
Alarm In 1&2
Ethernet Ports
Console
BYPASS
Connecting Alarm Circuits
After the device is installed, you are ready to connect the DC power and alarm connections.
Wiring the External Alarms
The device has two alarm input and one alarm output relay circuits for external alarms. The alarm input
circuits are designed to sense if the alarm input is open or closed relative to the alarm input reference
pin. Each alarm input can be configured as an open or closed contact. The alarm output relay circuit has
a normally open and a normally closed contact.
Alarm signals are connected to the device through the six-pin alarm connector. Three connections are
dedicated to the two alarm input circuits: alarm input 1, alarm input 2, and a reference ground. An alarm
input and the reference ground wiring connection are required to complete a single alarm input circuit.
The three remaining connections are for the alarm output circuit: a normally open output, a normally
closed output, and a common signal. An alarm output and the common wiring connection are required
to complete a single alarm output circuit.
The alarm connectors are on the device panel and are detailed in
Cisco ISA 3000 Industrial Security Appliance Hardware Installation Guide
3-40
Activity
Description
Alarm monitoring
Off — Alarm Out not configured or the system is off
(Default)
Green Steady on — Alarm Out is configured, no alarm
detected.
Red Steady on — Minor alarm detected
Red Flashing — Major alarm detected
Alarm monitoring
Off — Alarm In not configured or the system is off
(Default)
Green Steady on — Alarm In is configured, no alarm
detected.
Red Steady on — Minor alarm detected
Red Flashing — Major alarm detected
Link Status
Off — No link
Green Steady on — Link is up
Green Flashing — Transmitting and Receiving data
Amber — Fault, check log.
Port 1&2 or 3&4 LEDs flashing amber together — Those
two ports are in bypass mode and the system is up.
Console connection
Off — RJ-45 is being used for console
Status
Green — Mini USB is being used for console
Bypass Mode Indicator
The Ethernet LAN Ports pairs 1&2 or 3&4 (copper sku
only) will blink amber together every 100ms (fast blink),
when there is system power.
Chapter 3
Connecting the ISA 3000
Table 3-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isa3000-2c2f-k9Isa 3000